EasyManuals Logo

Rinstrum R300 Series User Manual

Rinstrum R300 Series
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Rinstrum - R300 Series Digital Indicator Operator Manual Rev 1.5
Page 17
6. Error Messages
6.1. Weighing Errors
Error Description Resolution
(U - - - - -) The weight is below the
minimum allowable weight
reading.
Increase the weight
or decrease the
minimum allowable
weight reading.
(O - - - - -) The weight is above the
maximum allowable weight
reading.
Warning - overloading may
damage mechanical scale
elements.
Check the condition
of load cell
connections. Check
for damaged load
cell.
(ZERO)
(ERROR)
The weight reading is beyond
the limit set for Zero
operation. The operation of
the <ZERO> key is limited in
the setup during installation.
The indicator cannot be
Zeroed at this weight.
Increase the Zero
Range (OPTION:
Z.RANGE) or use
the <TARE> key
instead.
(STABLE)
(ERROR)
Scale motion has prevented a
<ZERO>, <TARE> or
<PRINT> operation from
occurring on command.
Try the operation
again once the
scale is stable.

Other manuals for Rinstrum R300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinstrum R300 Series and is the answer not in the manual?

Rinstrum R300 Series Specifications

General IconGeneral
BrandRinstrum
ModelR300 Series
CategoryAccessories
LanguageEnglish

Related product manuals