Register Code Type Example Description
REG_SYSTEM_STATUS 0021
H
ULONG 00000200 Instrument Status
REG_SYSTEM_ERROR 0022
H
ULONG 00000000 Instrument Error
Status
REG_ABSOLUTE_MVV 0023
H
WEIGHT 00006187 Absolute signal in
mV/V
REG_WEIGHT_DISPLAY 0024
H
WEIGHT 000005DC Displayed weight
reading
REG_WEIGHT_USER 0025
H
WEIGHT 000005DC Gross or Net weight
REG_WEIGHT_GROSS 0026
H
WEIGHT 000005DC Gross weight
REG_WEIGHT_NET 0027
H
WEIGHT 000001F4 Net weight
REG_WEIGHT_TARE 0028
H
WEIGHT 000003E8 Tare weight
REG_WEIGHT_PEAK 0029
H
WEIGHT 000009C4 Peak held weight
REG_WEIGHT_HOLD 002A
H
WEIGHT 00000000 Manual held weight
REG_WEIGHT_TOTAL 002B
H
WEIGHT 000009C4 Total weight reading
REG_WEIGHT_LIVESTOCK 002D
H
WEIGHT 000001F4 Livestock weight
REG_WEIGHT_PT_TARE 002E
H
WEIGHT 000003E8 Preset Tare weight
REG_FULLSCALE 002F
H
LONG 00000BB8 Fullscale setting
REG_STREAM_DATA 0040
H
BLOB 0017ABC0000A… Block of data
selected by
STREAM_REGs
REG_STREAM_MODE 0041
H
OPTION
REG_STREAM_REG1 0042
H
MENU 00000001 Index for first
register data
REG_STREAM_REG2 0043
H
MENU 00000002 Index for second
register data
REG_STREAM_REG3 0044
H
MENU 00000005 Index for third
register data
REG_PASSCODE_FULL 00D0
H
ULONG 000004D2 Actual Full
Passcode
REG_PASSCODE_SAFE 00D1
H
ULONG 000009A4 Actual Safe
Passcode
REG_MENU_1 ..
REG_MENU_10
00E0
H
00E9
H
MENU Sub-menu items
REG_CAL_STAGE0 00F0
H
BLOB 3D570025000EF… Data block for stage
0
REG_CAL_STAGE1 00F1
H
BLOB 0BA302000FFFF… Data block for stage
1
REG_CAL_STAGE2 00F2
H
BLOB 08E0000000000… Data block for stage
2
REG_CAL_STAGE3 00F3
H
BLOB 00D8000D000E… Data block for stage
3
REG_WEIGHT_CALIBRATION 0100
H
WEIGHT 000005DC Weight used for
calibration
REG_CALIBRATE_ZERO 0102
H
EXECUTE
Calibrate Zero
command
REG_CALIBRATE_SPAN 0103
H
EXECUTE
Calibrate Span
command
REG_CALIBRATE_LIN1 ..
REG_CALIBRATE_LIN10
0104
H
010D
H
EXECUTE
Linearisation
commands
REG_ZERO_MVV 0111
H
WEIGHT FFFFFFFF Calibrated Zero
mV/V
REG_SPAN_WEIGHT 0112
H
WEIGHT 000009C4 Calibrated Span
Weight

Table of Contents

Other manuals for Rinstrum R323

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinstrum R323 and is the answer not in the manual?

Rinstrum R323 Specifications

General IconGeneral
BrandRinstrum
ModelR323
CategoryAccessories
LanguageEnglish

Related product manuals