7
manufacturer's guidelines of the product that is being handled must be followed
at all times. In addition, the national, federal and local regulations with regard to
the operation of appliances with a naked flame must also be respected.
To operate the appliance safely, you must follow the warnings mentioned above
as well as the guidelines provided by the manufacturer of the materials being
handled. The safety distance, the duration of exposure and the adjustment of
the appliance for the different materials being handled, depend on the
instructions provided by the manufacturer of the materials in question.
Always contact your RIPACK distributor for all maintenance work and spare
parts.
The RIPACK 2200 propane works with propane according to the principle
of atmospheric air burners induced at high speed (diagram B).
Ignition is performed using a piezoelectric lighter that is activated
simultaneously with the release of gas activated by the trigger, which is
the sole operating mechanism.
The RIPACK 2200 is a gun incorporating several safety mechanisms.
Its original and patented design ensures combustion without heating of the
combustion nozzle (cold nozzle).
A security valve system cuts off the gas supply in the event that the hose
breaks or tears.
An automatic safety device (so-called dead man's switch) cuts the supply
of gas automatically if the trigger is released. This stops the heating
immediately. This dead man's device must never be blocked in the open
position in any way.
A guard in front of the trigger prevents untimely operation.