- 19 -
C
LEANING
THE
VENTURI
:
The venturi must be cleaned in dry condition
.
• Clean the venturi with a
paintbrush or a hard brush.
• Apply compressed air in the
direction of the jet/nozzle to avoid
polluting the jet.
• Test the operation by performing
the procedures in the chapter
"Operation". If the gun has not
regained its full power, clean the
jet.
C
LEANING
THE
JET
:
Remove the jet cover with a screwdriver.
With an appropriate screwdriver, release
the jet, put it down, rinse it with petrol and
blow out.
• Reassemble the jet after you have
dried the O-ring on top.
• Fasten the injector without forcing it.
• Carefully reassemble the jet cover by
screwing it all the way without forcing it and
make sure the cover is flat on the injector
support.
• Test the operation by performing the
procedures in the chapter "Operation".
FOR ALL OTHER INTERVENTIONS
RELATED TO THE GAS CIRCUIT,
PLEASE CONTACT YOUR RIPACK
DEALER.
M
AINTENANCE
OF
THE
FITTINGS
:
Lubricate the fittings with "molykote 1102 gas
cock grease" or equivalent" (code article
RIPACK : 137039).
Note: Sealing product NBR.