EasyManua.ls Logo

Risco Pro-24 - Page 42

Risco Pro-24
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation and Programming Manual
3-16
SYSTEM: TIME DEFINE (cont’d)
Quick Key Item Default Range Explanation
TIME DEFINE (cont’d)
1 1 7 Zone Test Times ---
specifies the Start Time and Zone Test Period for
Zone Testing (see page 3-32 for additional information)
1 1 7 1 Start Test At:
HR:00
MIN:00
00-24
00-59
1 1 7 2 Zone Test Period* 00 00-24
this feature permits an automatic self-
testing routine for a group of up to 16
zones; the concept and procedures are
fully explained, beginning on page 3-32
use the Start Test At
parameter to define
the time of day (expressed in 24-hour
terms) when the test should first be
performed
use the Zone Test Period parameter to
define how often (every hour to every 24
hours), after the initial test is conducted,
that each subsequent test will occur
*Not for UL Installations