Before beginning:
• be sure that the panel is powered up and operating properly, that it’s wired to at least one
LCD Keypad, and has been programmed with its own unique configuration
•
install the Program Transfer Module on the Pro-24’s J1 connector; be sure its red LED is facing
forward.
•
move the Pro-24’s DEFAULT jumper (J2) so that it covers both pins
To Load a Panel’s Programmed Configuration into the Program Transfer Module:
1- Enter the Installer Programming mode from an LCD Keypad.
2- Without making any changes, exit the Installer Programming mode.
3- Note that the LED on the Program Transfer Module flashes rapidly at this time and the LCD Keypad displays:
4- When the LED stops flashing, the keypad will beep twice and display:
5- Remove the Program Transfer Module from J1 and remove the DEFAULT Jumper J2. For safekeeping,
secure it around one of the two pins.
6- The Program Transfer Module is now storing a copy of the panel’s configuration.
To Load the Program Transfer Module’s Stored Configuration Into an Pro-24:
1- Momentarily remove all power from the panel (both AC and Standby Battery).
2- Restore all power to the panel. After a moment, the LED on the Program Transfer Module will flash rapidly and
the LCD Keypad will display:
3- When the LED stops flashing, the keypad will beep once, and its display will return to normal.
4- Remove the Program Transfer Module from J1 and take off the DEFAULT Jumper (J2). For safekeeping,
secure it around one of the two pins.
5- Next, enter the Installer Programming mode from the LCD Keypad.
6- Without making any changes, exit the Installer Programming Mode.
7- The configuration in the Program Transfer Module’s has now been transferred to the Pro-24. You must now
reset its TIME and DATE, which were lost when power was removed.
SAVING DATA IN
EE U/D ACCESSORY
DATA IS SAVED
READY
RISCO
Please Wait ...