EasyManua.ls Logo

Risco RP432MP0000A User Manual

Risco RP432MP0000A
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
LightSYS Plus
Installation and Programming Manual

Table of Contents

Questions and Answers:

Risco RP432MP0000A Specifications

General IconGeneral
ManufacturerRisco
ModelRP432MP0000A
Detection Angle90°
Wireless Frequency868MHz
Detection Range12m
Mounting Height2.2m
Temperature Range-10°C to +55°C
Operating Temperature-10°C to +55°C

Summary

Important Notice

Introduction

System Architecture

System Capabilities

Main Capabilities

Compliance Statement

Main Features

Live Video Verification with VUpoint IP Cameras

Explains the integration of IP cameras for real-time video verification of events.

Flexible Communication Options

Advanced Communication Modules

Lists the plug-in GSM and built-in IP modules that enable system communication.

Multiple Reporting Destinations

Defines where system events are reported: System Users, Monitoring Stations, and Installers.

Cloud Communication

Describes how cloud connectivity enables remote monitoring and control via apps.

Monitoring, Notification, Operation and Control via RISCO Cloud

Self-Monitoring for System Users via Smartphone & Web Applications

Details how users can monitor and control their systems remotely via apps.

iRISCO Smartphone App

Describes the mobile app for smart and easy system control, notifications, and verification.

Web User Interface

Explains system monitoring and configuration via a web browser.

Enhanced Capabilities of Multi-Socket Communication Modules

Parallel Communication

Backup Communication

RISCO Bus Configurations

System Configuration Interfaces

Lists the methods for system configuration: wired keypad and configuration software.

Installation and Device Allocation Tools

Covers tools like Auto Setting, Bus Test, and calibration for device setup.

Diagnostic Tests and Maintenance Features

Details available tests for system operability, diagnostics, and maintenance.

Event Logging

Programmable Outputs

False Alarm Reduction Features

Home Automation

Safety Warnings and Precautions

Installation

Main Tasks for Initial System Setup

Outlines the typical order of tasks for setting up the system.

System Installation

Details the five steps involved in the physical installation of the system.

System Initialization, Device Allocation & General System Configuration

Covers powering up, language selection, device allocation, and system configuration.

Installer Programming

Explains how installers define parameters and access programming menus.

System Testing

Describes recommended tests for verifying system operability after installation.

Installer Responsibilities for Assisting the Client

Lists key areas where installers should assist clients upon handover.

Step 1: Creating a Plan for Mounting the System

Main Panel Mounting Considerations – Wireless Systems

Focuses on optimal placement for wireless systems, considering RF reception.

RF Signal Loss Due to Common Building Materials

Central Mounting Location – Wireless Systems

Step 2: Wiring, Settings, and Module Installations at the Main Panel

Power Supply, Ground

Covers wiring the power supply and grounding requirements for the system.

Main Panel Wiring Diagram

Replacing the Main Panel PCB

Main Panel Initial Settings

Details initial settings for Bell, Default, Bell tamper bypass, and Box tamper bypass.

Describing Connectors & Ports on the Main Panel PCB

Installing Plug-In Communication and Audio Modules

Guide for installing communication and audio modules, emphasizing power precautions.

Installing a GSM Module

Step-by-step instructions for installing a GSM module, including SIM card and antenna.

Connecting to IP

Connecting to Wi-Fi

Installing an LRT Module

Installing the Voice Module

Installing the Listen-In & Speak Unit

Wiring other Devices at the Terminal Block

Connecting a Wired Keypad

Explains the importance and connection of a wired keypad for initialization and scans.

Connecting Auxiliary (12 V DC) Devices

Details connecting auxiliary devices requiring 12V DC power to the AUX terminals.

Connecting the Bell / Loudspeaker

Connecting the Bell Tamper

Connecting the Box Tamper (Wall Tamper)

Connecting 4-Wire Smoke Detectors

Step 3: Bus Line Installations

Bus Line Wiring

Explains the wiring connections for the 4 wires of each RISCO bus line.

Describing Bus Devices

Defines peripheral devices connected via bus line as 'bus devices'.

Describing Bus Detectors and their Connection Options

Explains connecting bus detectors via Bus Zone Expanders (BZEs).

Typical Wired Expansion Modules Installed on RISCO Bus Lines

Describing Installer-Set ID Numbers for Bus Devices

ID Number Formats

Assigning ID Numbers (Setting DIP Switches) for Bus Devices

Installing Bus Devices

Installing Wired Keypads

Steps for installing wired keypads, including DIP switch settings and wiring.

Installing Bus Detectors

Guide for connecting individual bus detectors to the main panel PCB.

Installing Bus Zone Expanders

Connecting Multiple Bus Detectors using Bus Zone Expanders

Illustrates how to connect multiple bus detectors using BZEs.

Installing Power Supply Expansion Modules

Installing Utility Output Expansion Modules

Installing Wireless Expanders

Installing Bus Sounders (Sirens)

Step 4: Connecting Relay Detectors

Installing Zone Expanders

Defining Zone Termination Resistance

Wiring Resistors for Zone Termination Resistance

Zone Termination Configuration Options

Step 5: Connecting the Backup Battery and Mounting the Main Panel

Connecting the Backup Battery

Instructions for connecting the rechargeable backup battery, including warnings.

Mounting the Main Panel

Guidance on closing the enclosure and mounting the main panel on the wall.

System Initialization, Device Allocations & General System Configuration

Step 1: Describing Keypad Controls and Installer Menus

Explains keypad controls and navigation within installer menus.

Describing Dynamic Keypad Menus

Details how keypad menus adapt based on connected devices.

Table of Keypad Buttons

Describes the functions of typical Elegant/Panda keypad buttons.

Designating Labels

Entering the Installer Programming Menu at Initial System Setup

Step 2: Powering-Up and Initializing the System

System Power-Up and Language Selection

Guide for powering up the main panel and selecting the system language.

Defining Partitions

Keypad Timeout

Explains the keypad timeout behavior during installer programming.

Defining Partitions after Initialization

Steps to define the number of partitions after the initial system setup.

Step 3: Allocating and Configuring Installed Components

Auto-Setting Scan for Communication Modules & Bus Devices

Explains the auto-setting scan to find, enable, and configure modules and devices.

Describing Auto-Setting Results

Performing a Bus Test

Manually Allocating & Configuring Communication Modules

GSM Modules

Instructions for allocating and configuring GSM modules.

Entering or Deleting a SIM Card PIN

Guide on entering or disabling the SIM card PIN for GSM module operation.

Defining APN Automatically and Manually

Setting Dynamic IP / Static IP

Long-Range Radio Transmitter Module

Cellular On Bus (COB)

Manually Allocating and Configuring STU Adapter

Manually Allocating & Configuring other Modules and Bus Devices

Wired Keypads

Detailed steps for allocating and configuring wired keypads, including ID and partition settings.

Zone Expanders

Utility Output Modules

Power Supply Modules

Wireless Expanders

Wireless Video Expanders

Wireless Security Modules

Proximity Key Readers

Voice Module

Sounders (Sirens)

Bus Zones (Bus Detectors)

Bus Zone Expanders

Step 4: Allocating Wireless Zones

Allocating Wireless Expanders

Steps to allocate wireless expanders before their respective devices.

Allocating Wireless Devices

Allocating Wireless Devices via RF Transmission

Procedure for allocating wireless devices by sending an RF transmission.

Allocating Wireless Devices via Code

Step 5: Basic Zone Configuration for All Zone Types

Defining Basic Parameters

Explains defining zone parameters using 'One By One' or 'By Category' options.

Describing Zone Information Displayed at the Keypad

Shows how zone information is displayed on the keypad.

Defining Zone Parameters using the “One-By-One” Option

Defining Zone Parameters using the “By Category” Option

Defining Zone Termination Resistance using the “Resistance” Option

Step 6: Advanced Zone Configuration for Bus Zones and Wireless Zones

Advanced Programming for Bus Zones

Steps for configuring advanced parameters for bus zones.

Advanced Programming for Wireless Zones

Steps for configuring advanced parameters for wireless zones.

Measuring Background Noise Level and Defining the Threshold Limit

Performing a Wireless Comm. Test for Measuring Signal Strength

Step 7: Configuring System Communication

Defining Primary Communication Channels & Parameters

Details parameters for GSM, IP, and other communication methods.

Defining Communication with the Monitoring Station

Enabling Monitoring Station Communication

Steps to enable communication with the monitoring station.

Defining Monitoring Station Account Parameters

Sets up account numbers, reporting types, and communication channels for monitoring stations.

Step 8: Configuring Cloud Connectivity

Enabling / Disabling Cloud Communication

Instructions for enabling or disabling the default cloud communication feature.

Defining RISCO Cloud Connectivity

Sets network parameters like IP address, port, and channel for RISCO Cloud connection.

Step 9: Configuring Common System Parameters

Defining System Users

Explains setting up user codes, authority levels, and partition access.

Defining User Codes

Detailed steps for assigning user codes, partitions, and authority levels.

Changing the Default Installer Code

Changing the Default Grand Master Code

Resetting the Installer, Sub-Installer and Grand Master Codes to Default Codes

Defining Follow Me Destinations

Enabling Follow Me

Steps to enable the Follow Me feature for destinations.

Defining Follow Me Parameters

Sets parameters for Follow Me destinations like report type and partition.

Defining System Timers

Defining All Additional Parameters

Installer Programming

Defining Parameters – Installer Programming Menu

Describes the main sub-menus within the installer programming menu.

System

Timers

Specifies time durations for operations like entry/exit delays and bell timeout.

Controls

Advanced Controls

Communication Controls

EN 50131 Controls

PD6662 Controls

CP-01 Controls

Device Controls

Labels

Sounds

Tamper Sounds

Sets tamper sound parameters for during disarm and during arm.

Settings

Automatic Clock

Service Information

Firmware Update

Zones

Parameters

Covers basic zone parameter configuration methods: One-By-One, By Category, and Resistance.

Zone Parameters by Category

One-By-One Zone Parameters

Defines all parameters for one zone at a time.

By Category Zone Parameters

Defines specific parameters for multiple zones simultaneously by category.

Zone Label Configuration

Zone Partition and Group Configuration

Zone Partition

Assigns zones to partitions (up to 32) and groups (A-D).

Group Configuration

Defines groups within partitions for arming specific areas.

Zone Type Configuration

Advanced Zone Parameters

Forced Arming

Enables or disables using forced arming for zones, allowing arming of faulty zones.

Pulse Counter

Counts open/close pulses for zones; triggers if predefined number is exceeded.

Abort Alarm

Defines if zone alarm reports to monitoring station are immediate or delayed.

Bus Zone Parameters

Presence Zone Configuration

Bus Zone: OPR12 (WatchOUT PIR) Configuration

Bus Zone: iWISE DT Grade 2 Configuration

Bus Zone: (Industrial) Lunar /BWare/iWISE DT Grade 3 Configuration

Bus Zone: iWISE QUAD Grade 2 Configuration

Bus Zone: iWISE/BWare QUAD Grade 3 Configuration

Bus Zone: ODT15 (WatchOUT DT) Configuration

Bus Zone: WatchIN DT Grade 3 Configuration

Bus Zone: Seismic Configuration

Wireless Zones Configuration

Wireless Zones: 1-Way and 2-Way Smoke Configuration

Wireless Zones: 2-Way PIR, WatchOUT and Wireless IR Beam Configuration

Wireless Zones: 2-Way Magnetic Contact Detector (X73) Configuration

Presence Zone Configuration

Resistance Configuration

Testing

Self Test

Automated self-test for intrusion sensors, configurable for up to 16 zones.

Soak Test

Cross Zones Configuration

Alarm Confirm

Confirm Partition

Specifies partitions for alarm sequential confirmation.

Confirm Zones

Defines zones for alarm sequential confirmation, relevant for intrusion alarms.

Outputs

Nothing

Parameter for disabling a previously enabled utility output.

System Output Events

Defines parameters that follow system events, such as bell follow and communication failure.

Partition Output Events

Defines parameters that follow partition events, such as ready, alarm, and arm follow.

Zone Output Events

Defines parameters that follow zone events, allowing activation by groups of zones.

Code Output Control

Defines parameters for enabling codes to activate or deactivate utility outputs.

Pattern of Operation for Utility Outputs

Latch N/O & Latch N/C Operation

Defines latching logic for utility output activation/deactivation.

Pulse N/O & Pulse N/C Operation

Defines pulsing logic for utility output activation.

STU Testing

Codes

User Code Management

Defines user codes, authority levels, and partition assignments.

Grand Master Code Settings

Defines the Grand Master code, used by the system-responsible owner.

Installer Code Settings

Sets the installer code (default 1111) for accessing programming menus.

Sub Installer Code Settings

Sets the sub-installer code (default 2222) for limited access.

Code Length Configuration

Defines code length (4 or 6 digits) for all users and installers.

Communication

Method Configuration

Sets communication channel parameters for PSTN, GSM, IP, and LRT.

GSM Communication Parameters

Parameters for communication over GSM/GPRS/3G/4G network, including timers and SIM settings.

IP Communication Parameters

Parameters for IP network communication, including IP configuration and email settings.

LRT (Long-Range Radio Transmission) Configuration

Parameters for setting up a long-range radio communication network.

Monitoring Station Configuration

Report Type Settings

Defines the communication type (Voice, IP, SMS, LRT, SIA IP) for each MS account.

Monitoring Station Accounts

Defines account numbers for each monitoring station (MS 1-3) and their formats.

Partition (MS Accounts per Partition) Configuration

Specifies which monitoring station accounts notify upon events for selected partitions.

Communications Format Settings

Enables system communication to the monitoring station using Contact ID or SIA formats.

Monitoring Station Controls

Programmable controls related to communication with the monitoring station.

Monitoring Station Parameters

Programmable parameters related to MS operation, including retries and alarm restore.

MS Times Configuration

Allows programming timers for monitoring station communication, including Periodic Test.

Report Split Configuration

Routes specified events to up to three monitoring station receivers.

Report Codes Configuration

Views or programs codes transmitted to report events to the monitoring station.

Configuration SW Configuration

Security Settings

Sets parameters for technician remote communication, including access codes.

Controls Settings

Programmable controls related to remote configuration software sessions.

Gateway Settings

Specifies IP and port address for PC connection to configuration software.

Follow Me Configuration

Define FM Destinations

Sets up Follow Me destinations with information like type and label.

Follow Me Controls

Programmable controls related to Follow Me operation, like disarm stop and disable report at stay.

Follow Me Parameters

Programs parameters for Follow Me operation, including retries and voice message recurrence.

Cloud Communication Configuration

Audio Configuration

Messages Configuration

Customizes spoken messages for zones, partitions, outputs, macros, and opening messages.

Local Announcements Configuration

Announces security situations to occupants via the Listen-In & Speak unit.

Install Menu

Bus Devices Management

Provides access to bus device management: automatic, manual, testing, and bus speed.

Automatic Bus Scan

Performs an automatic bus scan to recognize and configure bus devices.

Manual Bus Device Configuration

Manually add or remove bus devices and set their parameters.

Bus Devices Testing

Performs bus scans and manual auto-setting scans for system testing.

Bus Speed Configuration

Selects bus speed for PIR Camera to Wireless Video Expander picture transfer.

Wireless Devices Management

RX Calibration

Measures background noise and defines threshold limits for wireless devices.

Allocation of Wireless Devices

Covers allocating wireless devices via RF transmission or by code.

Delete Wireless Device Allocation

Sub-menu to delete the allocation of a wireless device.

Devices Configuration

Keypad Configuration

Configures keypad parameters like label, partition, masking, controls, and serial number.

Keyfob Operation Modes

Defines operation modes for 1-way and 2-way keyfob buttons.

Sounder Configuration

Defines parameters for external sirens connected as bus accessories.

Proximity Key Reader Configuration

Defines or modifies parameters for Proximity Key Readers, including masking and controls.

Power Supply Configuration

Defines or modifies parameters for power supply expansion modules.

Exiting Installer Programming Menu

Exiting Installer Programming Menu after Initial System Programming

Step-by-step guide to exit the installer programming menu after initial configuration.

Restoring Manufacturer's Programming Defaults

Defining Parameters – Additional Installer Menus

Activities Menu

Contains parameters for keypad sound, advanced settings, Wi-Fi, and Follow Me.

Service Mode Configuration

Activates/deactivates service mode to silence alarms for battery replacement.

MS Test Procedure

Initiates a test message to the monitoring station.

Wi-Fi Scan and Connection

Scans for available Wi-Fi networks and connects to a selected network.

Follow Me Menu

Define FM Destinations

Sets up Follow Me destinations with information like type and label.

View Menu

Allows viewing system troubles, alarm memory, partition status, and service information.

Clock Menu

Sets system time, date, and configures automated system operations via schedules.

Event Log Menu

Maintenance Menu

Walk Test Procedure

Tests detector operation by simulating alarm events.

Keypad Test

Momentarily tests keypad indicators.

Siren Test

Activates alarm sound from bus sounders and utility outputs.

Strobe Test

Activates strobes in connected sounders and utility outputs.

Wireless Test

Tests keyfobs, wireless zones, and keypads for communication and signal strength.

Diagnostics Tests

Performs diagnostic tests on the main battery and zone resistance.

Macro Menu

Stand Alone Keyfob Menu

Testing the System

Installer Responsibilities for Assisting the Client

Appendix A: Technical Specification

Main Panel Technical Information

Details input power, current consumption, battery, output voltage, and dimensions.

Appendix B: Wiring Guidelines

Resistance per AWG Size and Distance

Table showing resistance values for different wire gauges and lengths.

Wiring Distance between Panel and Plug-In Transformer

Table showing recommended wire distances for panel to transformer connections.

Maximum Combined Length of Expansion Bus Wiring

Table indicating maximum combined lengths for expansion bus wiring by wire gauge.

Appendix C: Installer Event Log Messages

Appendix D: Troubleshooting

Main Panel PCB LEDs

Details the color, state, and status of LEDs on the main panel PCB.

GSM Module LEDs

Describes the function and status of LEDs on the GSM module.

Appendix E: Library Voice Messages

Appendix F: Monitoring Station Report Codes

Appendix G: Remote Software Upgrade

Step 1: Set parameters for IP/GPRS/3G/4G communication

Defines required parameters for GPRS/3G/4G or IP communication.

Step 2: Enter the location of the firmware update file

Specifies how to enter server IP, port, and file name for firmware updates.

Step 3: Activate the Remote Upgrade from the keypad

Guides on activating the remote upgrade process from the keypad.

Appendix H: Compliance

Possible Logical Key Calculations

Explains logical code structures, digit usage, and disallowed codes.

Possible Physical Key Calculations

Describes physical key implementation in wireless keyfobs and their recognition process.

System Monitoring

Details how the main unit and wireless elements are monitored.

Setting the LightSYS Plus to comply with EN 50131 Requirements

Appendix I: LightSYS Plus Accessories

Main Panel and Enclosures

Lists the main panel board and enclosure options.

Communication Modules

Lists available communication modules like 2G, 4G, and Wi-Fi.

Keypads

Lists various keypad types, including Elegant, LCD, and Panda.

Wired Bus Accessories

Lists wired bus accessories like zone expanders and output modules.

Appendix J: Installer Programming Maps

Installer Programming Menu Overview

Hierarchical listing of all parameters accessible through the installer programming menu.

System Menu Parameters

Covers system settings, including timers and controls.

Controls Menu Parameters

Details basic and advanced controls, including arming, bypass, and communication settings.

Advanced Controls Parameters

Lists advanced control parameters such as verification, code management, and area settings.

Related product manuals