Note: This operating mode
requires the knowledge of the
voltage/time parameters
suggested by the coupler
manufacturer
6
, prior to the
beginning of welding. If, for
whichever reason, that
information is not available,
please contact the coupler
manufacturer before starting to
weld.
Press OK to access the manual
mode (in which you will be
required to enter voltage and
time).
The last voltage value set in will
be displayed.
Press B (Increase/Decrease) to
set the correct voltage. Press OK
to confirm.
The last time value set in will be
displayed.
Press B (Increase/Decrease) to
set the correct time. Press OK to
confirm.
Most Important!
Before-welding operations
(scraping and cleaning) are
compulsory to obtain a good
welding. Don’t press OK until you
have performed these
operations. Once you press OK
you will assume all responsibilities.
Attention please! You can stop
the welding at any time by
pressing STOP but you must
absolutely contact the coupler
manufacturer to know if the
coupler may still be welded once
cooled off.
The good outcome of the
welding cycle is confirmed by the
message “WELDING CORRECT!”
on the display.
Press STOP to return to the main
menu.