Step 4: Customizing Your Thermostat
Set Time of Day, Day of Week,
Temperature Differential,
Residual Cooling
1. Press SET and PROG/MAN.
Release simultaneously.
Press or to change time of day.
2. Press Press
to change day of week.
3. Press Press
to change 1st stage
temperature differential.
NOTE: THE TEMPERATURE DIFFERENTIAL IS FACTORY PRESET AT 1°. THIS MEANS THAT
WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM THE TEMPERA
-
TURE SETTING, THE SYSTEM WILL TURN ON. IF THE SYSTEM TURNS ON TOO OFTEN,
INCREASE THE TEMPERATURE DIFFERENTIAL
.
4. Press Press
to change 2nd stage
temperature differential.
NOTE: THE SECOND STAGE TEMPERATURE DIFFERENTIAL IS FACTORY PRESET AT 2°.
5. Press Press
to change
residual cooling.
NOTE: THE RESIDUAL COOL FEATURE WILL KEEP THE SYSTEM FAN ON FOR AN
ADDITIONAL
30, 60, OR 90 SECONDS AFTER THE COMPRESSOR CYCLES OFF IN COOL
MODE
. THE RESIDUAL COOL FEATURE CAN BE SET ONLY IN THE COOL MODE.
8
>
>
PROG
MAN
SET PROG/MAN COOL-OFF-HEAT-EM
AUX CHECK EMER
AUTO - ON
>
>
SET PROG/MAN
SET P
>
>
1=MO
2=TU
3=WE
4=TH
5=FR
6=SA
7=SU
SET P
>
>
SET
P
>
>
SET
P
>
>
>
>