To access the CALIBRATION setting and adjust the temperature, select OFF
and hold down
+
and
-
together for 3 seconds. Use
+
and
-
to adjust the
temperature from between -4°F and +4°F.
Press
-
to select F (Fahrenheit) or C (Celsius), and press
+
to select the
temperature scale.
Then press
-
to access the compressor short cycle DELAY setting. If the
compressor short cycle delay setting is ON, the compressor cannot be
turned on for at least 3 minutes after it was last turned off. Use
+
and
-
to adjust the compressor short cycle delay setting to ON or OFF. Wait
approximately 15 seconds or toggle the system switch to return to
normal operation.