Roboguard 28
3. Press and release all solid (on) LED's so only the red
tamper LED is left on.
4. Press and release the tamper button (LED off) or do nothing as the
keypad will time out and exit automatically.
5. Determine what caused the Tamper to trigger and correct the
problem.
NOTE: The Tamper indication will only be sent once per zone,
unless the tamper indication is reset.
RED Status LED FLASHING (Automatic battery and radio
strength test)
The status (auto-test) routine is very important. The Roboguard sends
an ‘auto-test’ radio signal to the keypad every 20 minutes. Should a
guard fail to report in, the keypad will indicate this by flashing the red
‘status’ LED and activate an output switch. To establish which
Roboguard is reporting the status condition and to reset the status
detect LED you must do the following.
NOTE: This alarm indicates potential communication problems
that may be due to bad radio reception, battery problems or
faulty TX or CPU PIRs.
1. Press and release the status button (status LED on, keypad is now in
status condition display mode)
2. The zone LED for the Roboguard that is “in status” will be solid (on).
3. Press and release all solid (on) LED's so only the red status LED is
on.
4. Press and release the status button (LED off) or do nothing as the
keypad will time out and exit automatically.
5. Determine what is causing the Roboguard to fail auto-test and
correct the problem.