3. Setup parameters
Press the “menu” button to choice mode need to set:
Table2. Parameters on LED display
To set height from torch to material in
auto mode by the potentiometer.
factory setting: U=150
Device will change to auto mode when
the arc voltage from:
[Voltage Set - Area for control] to
[Voltage Set + Area for control]
factory setting: A=75
This parameter determines the value
respond of Z axis motion.
Display the arc voltage value from
plasma cutter.
The delay time to send ARC_OK from
0.1 to 9.9s: THC will sent ARC_OK
signal after this delay, the main purpose
is Z axis not move down at the first time
of cutting.
factory setting: d=10 (1s)
The steady-state error a range in which
the voltage is set errored, in which there
are signals controlling UP/DOWN
v =0.1-9.9V (±0.1V -> ±9.9V),
factory setting: v = 3.0V (±3.0V)