14
MAINTENANCE
MAINTENANCE
Warning Always unplug the product before cleaning
Please read the following instructions before maintenance
1. Seat cleaning and removal
Use a soft and damp cloth or sponge to wipe off the body gently.
Warning DO NOT scrub or use harsh or abrasive chemical cleansers to clean the product. Only use
neutral product for cleaning.
For a thorough cleaning, you may need to detach the MULTICLIN .
1) Unplug the MULTICLIN prior to clean.
2) Push the release button located on the back right of the seat and slide out main unit from mounting
plate.
Warning DO NOT damage bidet hose, power cord, ground wire during the removal.
2. Nozzle cleaning
Please clean the nozzle periodically. Press for 3 seconds without occupied the seat the nozzle
will extend automatically for nozzle cleaning and please use a toothbrush to clean the nozzle and
wand gently.
Press button or after 60 seconds the nozzle will retract and return.
3. T-Valve Filter Cleaning
1) Turn tap water shutoff valve off completely
2) Flush the toilet to empty the water tank
Warning Failure to do so could result in leaking
or flooding.
3) Unscrew the filter from the T-Valve
(the end not connected to a hose)
4) Gently brush and clean the filter with water to
remove the clog.
5) Reconnect the filter to the T-Valve properly.
Warning Failure to do so could result in
leaking or flooding.
6) Turn the tap water shutoff valve back on.
Warning DO NOT use aggressive product to clean. Only use neutral
product for cleaning.
Warning DO NOT force the nozzle and nozzle head.
PRESS