EasyManua.ls Logo

Rockwell Automation Allen-Bradley 1756-HIST1G - Specifications

Rockwell Automation Allen-Bradley 1756-HIST1G
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24 FactoryTalk Historian Machine Edition Module
Publication
1756-IN611A-EN-P - February 2010
Specifications
Cat. No. 1756-HIST1G | 1756-HIST2G
Environmental Conditions
Operating
Temperature
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
0…60 °C (32…140 °F)
Non-operating
Temperature
IEC 60068-2-1 (Test Ab, Unpackaged Non-operating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Non-operating Dry
Heat),
IEC 60068-2-14 (Test Na, Unpackaged Non-operating
Thermal Shock):
-40…85 °C (-40…185 °F)
Relative Humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat):
5…95% noncondensing
Vibration IEC 60068-2-6 (Test Fc, Operating):
2g @ 10…500 Hz
Operating Shock IEC 60068-2-27 (Test Ea, Unpackaged Shock):
30g
Non-operating
Shock
IEC 60068-2-27 (Test Ea, Unpackaged Shock):
50g
Emissions CISPR 11:
Group 1, Class A
ESD Immunity IEC 61000-4-2:
4kV contact discharges
8kV air discharges
Radiated RF
Immunity
IEC 61000-4-3:
10V/m with 1 kHz sine-wave 80% AM from 80…2000MHz
1V/m with 1 kHz sine-wave 80% AM from
2000…2700MHz
EFT/B Immunity IEC 61000-4-4:
±1 kV at 5 kHz on communications ports
Surge Transient
Immunity
IEC 61000-4-5:
±1 kV line-earth(CM) on communications ports
Conducted RF
Immunity
IEC 61000-4-6:
10V/rms with 1 kHz sine-wave 80% AM from 150
kHz…80MHz

Related product manuals