FLEX 5000 Standard and Safety Digital I/O Modules
Catalog Numbers 5094-IB16, 5094-IB16XT, 5094-IB16S, 5094-IB16SXT, 5094-OB16, 5094-OB16XT, 5094-OB16S,
5094-OB16SXT, 5094-OW8I, 5094-OW8IXT
User Manual
Original Instructions

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley 5094-IB16S and is the answer not in the manual?

Rockwell Automation Allen-Bradley 5094-IB16S Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley 5094-IB16S
CategoryI/O Systems
LanguageEnglish

Summary

Chapter 1 Digital I/O Module Operation in a Logix 5000 Control System

Controller and Software Compatibility

Details compatibility requirements for FLEX 5000 I/O modules with Logix 5000 controllers and software versions.

Secure Access to the System

Provides options and best practices to secure the FLEX 5000 I/O module and system access.

Configuration via Logix Designer Application

Outlines the process of creating a Logix Designer project and transferring configuration data.

Protected Operations

Details restrictions on operations that could disrupt module operation based on operating mode.

Considerations Specific to Safety Modules

Highlights safety module features, type approval, certification, and suitability for specific applications.

Single-channel or Dual-channel Mode

Explains safety I/O module modes and their effect on safety application suitability levels.

Determine Conformity

Emphasizes using appropriate components and assessing conformity for safety standards.

Safe State

Defines the safe states for safety outputs (OFF) and safety input data (OFF).

Configuration Signature and Ownership

Explains how configuration signatures and ownership ensure module integrity and prevent errors.

Chapter 4 Output Module Features

Configurable Point-level Output State in Program Mode or Fault Mode

Allows configuring individual output points to specific states during Program or Fault modes.

Connection Fault Handling

Details how to configure output module behavior when a connection fault occurs.

Output Behavior Immediately After a Connection Fault

Describes how outputs behave based on the Fault Mode parameter when a connection breaks.

Short-Circuit Protection

Helps prevent output damage from excessive current by detecting short circuits or overcurrents.

Thermal Shutoff

Protects outputs from overheating due to excessive loads, automatically turning them off.

Chapter 5 Safety I/O Module Features

Safety Input Module Features

Describes features of FLEX 5000 I/O safety input modules (5094-IB16S, 5094-IB16SXT).

Safety Application Suitability Levels

Details suitability levels for safety applications based on SIL, PL, and Category standards.

Input Modules in CIP Safety Systems

Explains how safety input modules connect to safety devices and their configuration options.

Use Test Output with a Safety Input

Describes using test outputs with safety inputs for fault detection and configuration.

Safety Input Fault Reset

Explains module-level configuration for latching faults until reset via output tag.

Safety Output Module Features

Describes features specific to FLEX 5000 I/O safety output modules (5094-OB16S, 5094-OB16SXT).

Output Module in CIP Safety Systems

Explains how safety output modules connect to safety devices and their configuration options.

Safety and Safety Pulse Test Mode

Configures safety output channels for continuous testing (Safety Mode) or momentary power removal (Pulse Test).

Single-channel Mode

Describes single-channel operation for safety output modules and fault detection.

Dual-channel Mode

Explains dual-channel operation for safety output modules, where channels function as pairs.

Safety Output Fault Reset

Explains module-level configuration for latching faults until reset via output tag.

Fault and Status Reporting

Describes how safety modules report fault and status data via module tags in Logix Designer.

Chapter 6 Configure the Standard Module

Discover Modules

Explains how to automatically detect and add connected FLEX 5000 I/O modules to a project.

New Module

Details the manual method for adding FLEX 5000 I/O modules to a Logix Designer project.

Edit 5094-IB16 Module Configuration Categories

Details configuration categories specific to the 5094-IB16 module.

Chapter 7 Configure and Replace Safety Modules

Create a New Module

Guides on adding new safety I/O modules to an offline Logix Designer project.

Edit the Module Configuration Common Categories

Introduces common categories for configuring FLEX 5000 safety I/O modules in Logix Designer.

Safety Category

Allows setting RPI rates and Connection Reaction Time Limit configurations for safety modules.

Appendix A Troubleshoot Your Module

Use the Logix Designer Application for Troubleshooting

Explains how to use Logix Designer for troubleshooting, including warning signals and fault info.

Appendix C Application/Wiring Examples for Safety I/O Modules

Appendix D Safety Data for I/O Modules

FLEX 5000 I/O Safety Input Module Safety Data

Lists calculated safety data for 5094-IB16S/SXT modules, including PFD, PFH, and MTTF values.

FLEX 5000 I/O Safety Output Module Safety Data

Lists calculated safety data for 5094-OB16S/SXT modules, including PFD, PFH, and MTTF values.