Rockwell Automation Allen-Bradley ArmorBlock 5000 Series User Manual

Rockwell Automation Allen-Bradley ArmorBlock 5000 Series
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual
Original Instructions
ArmorBlock 5000 8-channel
IO-Link Master Module
Catalog Numbers 5032-8IOLM12DR, 5032-8IOLM12M12LDR,
5032-8IOLM12P5DR

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley ArmorBlock 5000 Series and is the answer not in the manual?

Rockwell Automation Allen-Bradley ArmorBlock 5000 Series Specifications

General IconGeneral
CategoryI/O Systems
ManufacturerRockwell Automation
BrandAllen-Bradley
Input Voltage24V DC
Environmental RatingIP67

Summary

Important User Information

WARNING

Identifies practices/circumstances causing explosion in hazardous environments.

ATTENTION

Identifies practices/circumstances leading to injury, death, or property damage.

SHOCK HAZARD

Alerts to dangerous voltage presence.

BURN HAZARD

Alerts to hot surfaces.

ARC FLASH HAZARD

Alerts to potential Arc Flash hazards and PPE requirements.

Chapter 1 Introduction

Controller and Software Compatibility

Secure Access to the System

Power the Module

Module and Device Operation

Requested Packet Interval (RPI)

Defines the rate of data exchange between controller and module.

Protected Operations

Chapter 2 Module Features

Module Inhibiting

Electronic Keying

Protected Mode for IO-Link Master Module

Restrictions Imposed By Implicit Protected Mode

Restrictions Imposed By Explicit Protected Mode

Chapter 3 I/O Channel Features

Input Timestamping

Configure Channel Output State in Fault Mode

Short Circuit Protection

Fault and Status Reporting

Chapter 4 Common Features of IO-Link Device Integration

IO-Link Device Inhibiting

IO-Link Device Electronic Keying

Automatic Device Configuration (ADC)

Data Storage

Device Correlation Check

Execute IO-Link Commands Through Explicit Messaging

Protected Mode for IO-Link Devices

Restrictions Imposed By Protected Mode

Chapter 5 Configure the IO-Link Master Module

Configure the Module IP Address

Configuring IP address, subnet mask, and gateway for module.

Use the BOOTP/DHCP Tool

Add the Module to a Studio 5000 Logix Designer Application Project

Discover Modules

New Module

Edit the Module Properties

Module Definition

Connection View

Internet Protocol View

Port Configuration View

Time Sync View

Switch Channel Mode from IO-Link or Fallback to Digital Output

Reset Module to Factory Default

Chapter 6 Configure the IO-Link Device

Add IO-Link Devices to Your Project

Add a Preconfigured Device

Edit the IO-Link Device Properties

Configuration View

Replace IO-Link Devices

Replace a Device with ADC Disabled and DS Not Supported

Replace with a Used Device when ADC Disabled and DS Supported

Replace a Device on a Fallback Channel

Replace with a Used Master Module when any Device Supports DS and ADC Disabled

Replace a Master Module and Devices with Device ADC Disabled

Adjust Device Configuration After Replacement

Clone/Duplicate a Machine

Reset IO-Link Device to Factory Default

Appendix A Troubleshoot Your IO-Link Master Module

Module Status Indicator

Describes module status indicators and recommended actions.

Network Status Indicator

Describes network status indicators and recommended actions.

Link Status Indicator

Power Status Indicator

Channel Status Indicator

Troubleshoot Wiring Issues

Use the Studio 5000 Logix Designer Application for Troubleshooting

Status and Fault Information in Module Properties

Module properties views for monitoring module status and faults.

Module Status on Module Properties Window

Module Fault Descriptions on Connection View

Module Fault Information and Diagnostics on Module Info View

Diagnostics in Studio 5000 Logix Designer Application

Module Diagnostics

Port Diagnostics

Channel Diagnostics

Studio 5000 Logix Designer Application Tag Editor

Module Diagnostic Webpages

Appendix B Troubleshoot Your IO-Link Device

Use the Studio 5000 Logix Designer Application for Troubleshooting

How Studio 5000 Logix Designer indicates fault conditions for devices.

Warning Signal in the I/O Configuration Tree

Warning icons in I/O Configuration tree indicating device faults.

Status and Fault Information in Module Properties

General Troubleshooting Tips for Configuration and Connection Issues

Fault and Status Information on Device Info View

IO-Link Event Log

Use CIP Messages to Retrieve the IO-Link Event Log

Appendix C IO-Link Master Module and IO-Link Device Tag Definitions

IO-Link Master Module Tags

Input Tags for IO-Link Master Module

Output Tags for IO-Link Master Module

Event Input Tags for IO-Link Master Module

Event Output Tags for IO-Link Master Module

Status Tags for IO-Link Master Module

IO-Link Device Tags

Configuration Tags for IO-Link Device

Input Tags for IO-Link Device

Output Tags for IO-Link Device

Appendix D Module Diagnostic Assembly

Diagnostic Channels

Create Message Type User Tags

Related product manuals