Describes the function and placement of redundant adapter pairs.
Details the process for obtaining an IP address for the primary module.
Guidance on installing the 24V DC power supply for the system.
Steps for mounting the 1715-A2A adapter base unit onto DIN rails.
Procedure for mounting the 1715-A3IO I/O base unit onto DIN rails.
Instructions for terminating power connections on the adapter base unit.
Explains connecting two independent 24V DC sources to the adapter base unit.
Instructions for connecting field wiring to termination assemblies.
Steps for connecting the adapter to the Ethernet network using DLR or Star topologies.
Instructions for installing the 1715-AENTR adapters.
Procedure for associating an IP address with the primary adapter's MAC address.
Steps for installing digital and analog I/O modules onto the base unit.
Safety precautions when using HART Pass-Through in a safety system.
Lists required software for configuration: RSLogix/Studio 5000 and RSLinx.
Instructions for installing adapter and I/O module Add-on Profiles.
Steps to create a new project and configure the controller.
Adds the 1715-AENTR adapter to the project and configures it for EtherNet/IP.
Details planning IP addresses and options for setting adapter IP addresses.
Instructions to add the 1715-IB16D module in Duplex and Simplex modes.
Instructions to add the 1715-OB8DE module in Duplex and Simplex modes.
Instructions to add the 1715-IF16 module in Duplex and Simplex modes.
Instructions to add the 1715-OF8I module in Duplex and Simplex modes.
Requirements for using 1715 I/O modules in SIL 2 safety applications.
Information on using 1715 I/O modules, including Simplex/Duplex modes.
Explains the functions of the 1715-AENTR adapter in SIL 2 applications.
Discusses input module behavior, status, and safety accuracy.
Steps to enable SIL 2 operation and set connection reaction time limits.
Configures output module actions for Program mode and fault conditions.
Introduces SIL 2 Add-On Instructions for verifying data integrity.
Steps to download and import SIL 2 Add-On Instructions into a project.
Instructions to configure an input module Add-On Instruction.
Instructions to configure an output module Add-On Instruction.
Explains how to calculate worst-case safety reaction time.
Describes how to perform a SIL 2 Reset for modules.
Describes calculating and setting threshold values for digital inputs.
Explains the three types of threshold diagnostics settings in Logix Designer.
Allows calculation and entry of custom threshold values.
Explains how to calculate diagnostic settings using known values.
Explains Probability of Failure on Demand (PFD) and per Hour (PFH).
Guidance on selecting appropriate values for SIL 2-certified systems.
Provides PFD and PFH calculated values based on module configuration.
Checklist for planning, programming, and startup of SIL 2 systems.