Do you have a question about the Rockwell Automation Allen-Bradley 1715-AENTR and is the answer not in the manual?
Series | 1715 |
---|---|
Model | 1715-AENTR |
Communication | Ethernet/IP |
Enclosure | IP20 |
Input Voltage | 24V DC |
Mounting Type | DIN Rail |
Number of Ports | 2 |
Housing Material | Polycarbonate |
Storage Temperature | -40...85 °C (-40...185 °F) |
Relative Humidity | 5 to 95% (non-condensing) |
Shock | 30 g |
Certifications | CE, UL, cUL |
Product Type | Ethernet I/O Module |
Network Address | IP Address Configurable |
Describes the system's structure with adapters and I/O base units.
Explains the fail-safe behavior of simplex I/O modules upon fault detection.
Details redundant input/output modules for fault tolerance and low/high demand applications.
Explains how redundant adapters handle IP address swapping during adapter faults.
Lists and describes the key components of the 1715 Redundant I/O System.
Specifies the required 24V DC power supply and compliance details.
Provides an overview of typical redundant I/O system layout and module positioning.
Details the mounting procedure of the system on DIN rails within an enclosure.
Procedures for assigning IP addresses to adapters via BOOTP/DHCP or RSLinx.
Explains the implicit I/O strategy for entering and exiting protected mode.
Details how to enable/disable the web server for diagnostic information.
Introduces digital I/O modules and their function in the system.
Explains how modules indicate hardware and software faults via status indicators.
Describes how to suspend module connections for maintenance or configuration.
Highlights features specific to the 1715-IB16D digital input module.
Introduces analog I/O modules and their integration into the system.
Explains how to set scaling factors for channel output current values.
Describes the different operating modes for analog input and output modules.
Details enabling external asset management systems to manage HART field devices.
Lists prerequisite tasks before configuring the system.
Specifies required software for configuration, including RSLogix/Studio 5000 and RSLinx.
Step-by-step guide to creating a new project and configuring the controller.
Process for adding the redundant adapter pair to the project's I/O configuration.
Procedures for assigning IP addresses to adapters via BOOTP/DHCP or RSLinx.
Outlines essential requirements for using the system in SIL 2 applications.
Presents common single and fault-tolerant configurations for safety applications.
Specifies conditions and requirements for energize-to-action configurations in safety systems.
Guides on enabling SIL 2 operation and setting reaction time limits.
Introduces the purpose and use of SIL 2 Add-On Instructions for data verification.
Steps to download and import SIL 2 Add-On Instructions into a project.
Guidance on creating a dedicated periodic task for SIL 2 safety logic.
Provides formulas and examples for calculating worst-case safety reaction times.
Overview of diagnostic functions provided by adapters and I/O modules.
Explains system faults indicated by Rack Status indicators on adapters.
Describes module faults indicated by Module Status and Rack Status indicators.
Details channel faults and their indication on Module Status and Rack Status indicators.
Details the status indicators for the 1715-AENTR adapter.
Explains the status indicators for the 1715-IB16D digital input module.
Details the status indicators for the 1715-OF8I analog output module.
Describes how to calculate and set threshold values for digital inputs.
Outlines the three types of threshold diagnostics settings in Logix Designer.
Guides on calculating threshold and resistor values for correct diagnostic settings.
Steps to reconfigure an I/O module using the Logix Designer application.
Explains Probability of Failure on Demand (PFD) and Probability of Failure per Hour (PFH).
Details values used for PFD/PFH calculations based on module configurations.
A checklist for planning, programming, and startup of SIL 2-certified systems using 1715 I/O modules.
Describes tags associated with the 1715-AENTR adapter.
Lists tags associated with the 1715-IB16D digital input module (Simplex).
Defines tags for the 1715-OB8DE digital output module (Simplex, Output).
Lists tags associated with the 1715-IF16 analog input module (Simplex, Input).
Lists updates and new information for the December 2020 revision.
Details updates for the March 2020 revision.