Rockwell Automation Publication 6300P-UM001B-EN-P - March 2021 35
Chapter 4 Configure, Restore, and Update System Settings
8. Press Enter.
9. Turn off power to the computer.
10. Remove the computer cover as detailed in Remove the Cover
on
page 44.
11. Move switch 3 of bank SW4 to off.
12. Reinstall the cover as detailed in Reinstall the Cover
on page 46.
13. Turn on power to the computer.
14. During POST, press F2 to enter the UEFI set-up utility.
15. Use the right (6) arrow to toggle over to the Save and Exit tab.
16. Use the down (2) arrow to toggle down and select Restore RealTime
Defaults or press F9 to select Optimized Defaults.
17. After you have selected the preferred UEFI setting, press F10 to save
and exit.
IMPORTANT The blue Warning box disappears after you press OK, but the
‘Warning: SW4-3 = ON’ message remains until you turn off power to
the computer.