EasyManuals Logo

roco MultiMAUS User Manual

roco MultiMAUS
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
52

3.5. “RESET“
The
multi
MAUS is a particularly user-friendly digital controller and can be reset to the factory settings,
not just completely but also partially.
3.5.1. “CANCEL” can be regarded as the emergency exit from this menu item.
3.5.2. When the “SETTINGS” are reset, all entries in the “Settings” menu are reset to factory set-
tings. The locomotive library remains intact. If calibration has been performed (see 3.5.6.), it
will have to be repeated after the reset.
3.5.3. Select this sub-item if you wish to delete the “LIBRARY”.
3.5.4. Select “SPEED STEPS” to reset the selection made in menu item 3.4 to the factory setting.
3.5.5. You can use “FACTORY RESET” to reset your
multi
MAUS completely to the original status. Any
entries made are deleted.
3.5.6. You will not normally have to “CALIBRATE” the
multi
MAUS as this is performed on delivery.
However, in the event of extreme temperature variations, the controller may need to be re-
adjusted, e.g. if a locomotive travels in the zero position. To do so, proceed as follows:
The first screen you see is the “START?” screen. To confirm, press the “Light / OK” key. “LEFT”
appears on the display screen.
– Turn the controller to the left as far as it will go. To confirm, press the “Light / OK” key.
“MIDDLE” appears on the display screen.
Turn the controller to the middle (zero position) and confirm by pressing the “Light / OK” key.
“RIGHT” appears on the display screen.
Turn the controller to the right as far as it will go. Once you have confirmed by pressing the
“Light / OK” key, you return to the start level “RESET”.
3.6.
“STOP-MODE“
In the event of an emergency, press the “STOP” key during drive mode to trigger an immediate emer-
gency stop. You determine the exact effect of the emergency stop in menu item “STOP MODE”.
3.6.1. “DISABLE VOLTAGE”: The entire system is disconnected from the voltage supply;
3.6.2. “EMERGENCY STOP”: All locomotives stop immediately but the voltage supply remains in
place.
You can still trigger a selective emergency stop which only affects the selected locomotive in spite
of this setting. See page 40.
Factory setting: DISABLE VOLTAGE
To confirm, press the “Light / OK” key. You return to the start level “STOP MODE”.
3.7.
“INFOS”
A menu item which provides you with information on the software version (“SOFTWARE”), the type
of X-Bus (“X-BUS”) and the current master (“COMMAND STATION”) in a digital system.
You call up the desired information using one of the “arrow keys”. You return to the start level by
pressing the “Light / OK” key.
3. THE “SETTINGS MENU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the roco MultiMAUS and is the answer not in the manual?

roco MultiMAUS Specifications

General IconGeneral
Control ProtocolDCC
DisplayLCD
Speed Steps14, 28, 128
ManufacturerRoco
CategoryController
TypeHandheld
Switching of turnouts and signalsYes
CompatibilityDCC systems
InterfaceXpressNet
Locomotive Control9999 locomotive addresses

Related product manuals