27
H70/200AC
74 Conguration of safety edge 2
0 → safety edge 1 OFF or not installed
1 → safety edge 1 SWITCH type, it inverts only in closing
2 → safety edge 1 RESISTIVE 8,2 kOhm type, , it inverts only in closing
3 → safety edge 1 SWITCH type, it always inverts
4 → safety edge 1 RESISTIVE 8,2 kOhm type, it always inverts
1
75
Encoder
0 → OFF
1 → ON OPTICAL ENCODERS (8 impulse per turn)
2 → ON MAGNETIC ENCODERS(1 impulse per turn)
0
76 Conguration of 1° radio receiver channel
0 → PP
1 → PEDESTRIAN
2 → OPEN
3 → CLOSE
4 → STOP
5 → COURTESY, the normal functionning is not enable, the relay is only managed by the radio receiver
6 → COURTESY PP, the normal functionning is not enable, the relay is only managed by the radio receiver.
It is like the step by step: on-off-on-off.. the device connected on courtesy light
7 → FLASHING LIGHT, the normal functionning is not enable, the relay is only driven by 1°radio receiver channel
8 → FLASHING LIGHT PP, the normal functionning is not enable, the relay is only managed by the radio
receiver, it is like the step by step: on-off-on-off.. the device connected on ashing light
0
77 Conguration of 2° radio receiver channel
0 → PP
1 → PEDESTRIAN
2 → OPEN
3 → CLOSE
4 → STOP
5 → COURTESY, the normal functionning is not enable, the relay is only managed by the radio receiver
6 → COURTESY PP, the normal functionning is not enable, the relay is only managed by the radio receiver.
It is like the step by step: on-off-on-off.. the device connected on courtesy light
7 → FLASHING LIGHT, the normal functionning is not enable, the relay is only driven by 2°radio receiver channel
8 → FLASHING LIGHT PP, the normal functionning is not enable, the relay is only managed by the radio
receiver, it is like the step by step: on-off-on-off.. the device connected on ashing light
1
78 Output conguration of ashing light
0 → FIXED output, the ashing is done through the electronics of the ashing light
1 → 1Hz, the output is on and off 1 time per second (1Hz), the ashing light must be a xed light one
2 → different ashing for opening and closing, the output is on and off 1 time per second (1Hz) in opening
and 2 times per second (2Hz) in closing, the ashing light must be a xed light one
0
79 Courtesy light time
0 → OFF
1 → IMPULSIVE, the output is on for a short time when it starts the movement
2 → the output is on during all movement time
3-90 → SECONDS after the end of the movement, in which the output is on and moreover it is on during
all movement time
92-99 → from 92 the second number indicates the MINUTES after the end of the movement, in which the
output is on and moreover it is on during all movement time (from 2 to 9 minutes)
60
80 Conguration clock input (ORO), closing the contact it causes an opening of the gate, while the opening of
the contacts causes the closing of the gate. You can choice 2 congurations:
0 → When the clock input (ORO) is closed, it ignores all inputs
1 → When the clock input (ORO) is closed, it accepts all inputs
0
90 Recall factory settings
After the control unit shows You the parameter 90, You have to push together the buttons “+” and “-“ for 5
sec.: the display will show You the word “rES-“ blinking, it means that the default value are resetted
n0 Serial number
00-FF → control unit model
n1 Serial number
00-99 → production year
n2 Serial number
00-52 → production week
n3 Serial number
00-99 → 1° progressive number
n4 Serial number
00-99 → 2° progressive number