065 75$16&(,9(5 ; $ ; $
Operator’s Manual • Use under Special Conditions
– 3.48 – 6076.0822.12.01
5 Press softkey
TX ALC LEVEL.
Enter value.
Entry of the ALC level in the range from
-6.5 dB to + 6.5 dB
Output level of TX ALC
0 dB is recommended.
6 Press softkey TX
ALC.
Switches the automatic level control
(ALC) for transmitter on or off.
13 Press softkey TX
LEVEL.
Enter value.
Entry of value for audio TX LEVEL into
600 Ω of interfaces NB1 and NB2 in the
range from -20 dB to +10 dB
For NB2 and device Link 11 (Menu 565
(DEVICE MAPPING)) the setting range is
between -3 and +3 dB.
For WB1 and WB2 the setting range is
between -3 and +15.5 dB relative to
1.4 V
pp
.
14 Press softkey RX
LEVEL.
Enter value.
Entry of value for audio RX LEVEL into
600 Ω of interfaces NB1 and NB2 in the
range from -20 dB to +10 dB
For NB2 and device Link 11 (Menu 565
(DEVICE MAPPING)) the setting range is
between -3 and +3 dB.
For WB1 and WB2 the setting range is
between -3 and +15.5 dB relative to
1.4 V
pp
.
No. Control Action Notes
Operation with ALC-TX
Setting Input range for constant modulation
depth or FM deviation
0 dBm -15 to +15 dBm
-15 dBm -30 to 0 dBm