065 75$16&(,9(5 ; 0 ; 0
Operator’s Manual • Use under Special Conditions
– 3.76 – 6076.0851.12.01
Example:
1. Defining the subnet mask
- depending on the number of networks and devices per network
(up to 256 networks with max. 253 devices per network => 255.255.255.000)
2. Defining the logical addresses and IP addresses
- Select a logical address that clearly identifies the particular device and is easy to re-
member.
- The logical and the local address may be identical.
3. Defining the gateway addresses
- For each local network a gateway address is required
(192.168.082.001, 192.168.083.001 and 192.168.084.001).
- For the local address always use "1".
4. Entering the logical addresses and IP addresses for those radios that are to be linked up
to
- We recommend to also enter the logical addresses and IP addresses of the control
units, because this will inhibit these addresses for radios and prevent multiple address
allocation.
5. Entering the own address, subnet mask and gateway address in Menu 836 (CU AD-
DRESS ROUTE)
Address
Logical Associated IP = network + local
46 192.168.082.010 192.168.082 010
47 192.168.082.011 192.168.082 011
48 192.168.082.012 192.168.082 012
50 192.168.083.010 192.168.083 010
51 192.168.083.011 192.168.083 011
52 192.168.083.012 192.168.083 012
55 192.168.082.020 192.168.082 020
68 192.168.084.010 192.168.084 010