Firmware V3.15
R&S
®
ZNB/ZNBT
17User Manual 1173.9163.02 ─ 54
3 Firmware V3.15
Version 3.15 of the R&S ZNB/ZNBT firmware provides the following changes:
New functionality
Measurement uncertainty analysis using METAS VNA Tools (option R&S ZNB-K50/
K50P) for all R&S ZNB models:
"METAS Calibration" using calibration kits with uncertainties
Real-time visualization of measurement uncertainty
Verification using verification kits with uncertainties
Real-time visualization of verification results
Export to METAS VNA Tools for offline analysis
See Chapter 5.7.7, "Measurement Uncertainty Analysis", on page 228
For the R&S ZNBT, this option is not available.
Transmission measurements: "parallel" converted impedance and admittance mod-
eling (in addition to "series" modeling). New measurement results and marker for-
mats
See "Parallel Transmission Impedance" on page 123
New software option R&S ZNB-K210/R&S ZNBT-K210 "Eazy De-embedding"
(EZD) based on IEEE 370
See Chapter 5.7.8, "Eazy De-embedding Based on IEEE 370", on page 230
New software option R&S ZNB-K220/R&S ZNBT-K220 "In-situ De-Embedding"
See Chapter 5.7.9, "In-situ De-Embedding", on page 232
New software option R&S ZNB-K230/R&S ZNBT-K230 "Smart Fixture De-embed-
ding"
See Chapter 5.7.10, "Smart Fixture De-Embedding", on page 232
New software option R&S ZNB-K231/R&S ZNBT-K231 "Delta-L 4.0 PCB Charac-
terization"
See Chapter 5.7.11, "Delta-L 4.0 PCB Characterization", on page 232
New "Disable all other Measurements" trace function:
Disables all channels, except the active one
Disables all traces in the active channel, except the active one
Hides all diagrams except the active one
The previous configuration can be restored using the complementary "Enable all
Measurements" function
See Disable all other Measurements/Enable all Measurements
New automatic gain control algorithm (R&S ZNB only!)
Note that the new "Memory AGC" algorithm has become the factory default for the
R&S ZNB. You can reactivate the legacy "Point AGC" algorithm in the "System
Config" dialog.
See "Global AGC (R&S ZNB only!)" on page 711.
Modified functionality
"Save Report" button in system info dialog relabeled to "Create R&S Support Infor-
mation"