Command Reference
R&S
®
ZNB/ZNBT
826User Manual 1173.9163.02 ─ 54
CALCulate:FMODel:ISD<Ph_pt>:PORT:ORDer.................................................................831
CALCulate:FMODel:ISD<Ph_pt>:PORT:SKIP................................................................... 831
CALCulate:FMODel:ISD<Ph_pt>:PORT:SKIP:LEFT.......................................................... 832
CALCulate:FMODel:ISD<Ph_pt>:PORT:SKIP:NONE......................................................... 832
CALCulate:FMODel:ISD<Ph_pt>:PORT:SKIP:RIGHt......................................................... 832
CALCulate:FMODel:ISD<Ph_pt>:RUN:RUN..................................................................... 832
CALCulate:FMODel:ISD<Ph_pt>:RUN[:STATe]................................................................. 833
CALCulate:FMODel:ISD<Ph_pt>:SCALe:ATTenuation....................................................... 833
CALCulate:FMODel:ISD<Ph_pt>:SCALe:FREQuency....................................................... 833
CALCulate:FMODel:ISD<Ph_pt>:SCALe:FTIMe................................................................833
CALCulate:FMODel:ISD<Ph_pt>:TRACe:COUPling.......................................................... 834
CALCulate:FMODel:ISD<Ph_pt>:ATTenuation:BEHavior <AttenuationBehavior>
Sets/gets the linear_2x batch mode parameter of the ISD tool:
LINear (parameter value 1): Used for linear insertion loss of test coupon
NONLinear (2): Used for non-linear insertion loss of test coupon
RESonant (3): The 2x thru test coupon will be split and used directly for deembed-
ding.
This option may be more accurate when the fixture and 2x Thru have the same
impedance at every location
Suffix:
<Ph_pt>
.
This suffix is ignored.
Parameters:
<AttenuationBehavior>RESonant | LINear | NONLinear
Manual operation: See "Test Coupons > Insertion Loss" on page 599
CALCulate:FMODel:ISD<Ph_pt>:COUPon:MEASure
For a fixture modeling with the ISD tool and coupon types SYMMetric2x | OPEN1x |
SHORt1x (see CALCulate:FMODel:ISD<Ph_pt>:COUPon:TYPE), this command
starts the measurement of the coupon at the active ports (see CALCulate:FMODel:
ISD<Ph_pt>:COUPon[:STATe]).
Suffix:
<Ph_pt>
.
This suffix is ignored.
Example: See Chapter 9.2.8, "Fixture Modeling", on page 1417
Usage: Event
Manual operation: See "Measure / Measure Open / Measure Short" on page 594
CALCulate:FMODel:ISD<Ph_pt>:COUPon:MEASure:FILename <String>
For a fixture modeling with the ISD tool and coupon types SYMMetric2x | OPEN1x |
SHORt1x (see CALCulate:FMODel:ISD<Ph_pt>:COUPon:TYPE), this command
loads the coupon properties from a Touchstone file.
SCPI Command Reference

Table of Contents