D Series with DELTA Ultimate technology
• Anti legionnaire´s disease
The water heater is automatically set to
over 60ºC for at least one hour once a
week. Whilst this mode is active, you will
see the following screen.
Within the legionella function you can
choose the time period in days for the
activation of the legionella function. (By
default this period is 7 days)
ANTILEGIONAIRE’ S
DISEASE FUNCTION
PERIOD (DAYS)
7
• Effective Power Function
This function shows the working time
and total time that the product has
been connected on the main screen.
The nominal and effective power will
appear on the screen after 6 seconds
without pushing any buttons.
24 00
The effective power is the actual consumption of our product
during the total time it is switched on.