20
Mar. 2008 GT-10
5. Verify that the waveform display on the oscilloscope is like that shown in
the figure below.
fig.11usbdout1.eps
Upper: left channel, lower: right channel
* The output level may vary according to the device capable of digital input.
6. Subject the product to vibration and verify that no noise or other
abnormal sound is heard from the monitor speakers.
7. Press [ ] to advance to the next test.
12. OUTPUT&MUTE
Testing of SEND, PHONES, OUTPUT L/R, the MUTE
Circuitry for each output, and the OUTPUT -10/+4
dB Switching Circuitry
fig.12output&mute2e.eps
SEND Test
1. Using a cable with a 1/4-inch phone plug, connect the SEND jack to
channel 1 on the oscilloscope and the left-channel monitor speaker.
2. Verify that the output waveform display on the oscilloscope is as shown
in the figure below, and that no waveform is displayed while MUTE is
displayed on the screen.
fig.12out-send.eps
3. Verify that the peak value is from 1.25 to 1.35 V.
4. Verify that signals are output from the monitor speakers and no noise or
other abnormal sound is heard, and that no sound is played while MUTE
is displayed on the screen.
PHONES Test
1. Using a cable with a 1/4-inch stereo phone plug (with 33-ohm load
resistor), connect the PHONES jack to channel 1 and channel 2 of the
oscilloscope and to the left-channel and right-channel monitor speakers.
2. Verify that the INSERT PHONES message disappears from the screen.
3. Verify that the output waveform display on the oscilloscope is what is
shown in the figure below, and that no waveform is displayed while
MUTE is displayed on the screen.
fig.12out-phones.eps
Upper: left channel, lower: right channel
4. Verify that the peak value for both the left and right channels is 0.95 to
1.05 V (with 33-ohm load).
5. Verify that signals are output from the monitor speakers and no noise or
other abnormal sound is heard, and that no sound is played while MUTE
is displayed on the screen.
* Leave the a 1/4-inch stereo phone plug connected to the PHONES jack on the
GT-10.
Testing of OUTPUT L/R and the Monaural Jack
Switch
1. Using the two cables with 1/4-inch phone plugs, connect the OUTPUT L
and R jacks to channel 1 and channel 2 of the oscilloscope and to the left-
channel and right-channel monitor speakers.
2. Verify that the output waveform display on the oscilloscope is what is
shown in the figure below, and that no waveform is displayed while
MUTE is displayed on the screen.
fig.12out-out.eps
Upper: left channel, lower: right channel
3. Verify that the peak value for both the left and right channels is 1.55 to
1.75 V.
4. Verify that signals are output from the monitor speakers and no noise or
other abnormal sound is heard, and that no sound is played while MUTE
is displayed on the screen.
5. Detach the plug from the OUTPUT R jack.