Settings Common to All Modes (System Function)
 
[F1 (GENERL)]
[F2 (TRIGGER)]
[F3 (ASSIGN)]
System Menu [F5 (D BEAM)]
 
Parameter
Value Explanation
SENSIBILITY
 
D Beam Sens
0–127 This sets the D Beam controller’s sensitivity.
The higher the value set, the more readily the D Beam Controller goes to into erect.
 
PART
 
D Beam Part Select
KBD, PAD Part controlled by the D Beam controller
 
Parameter
Value Explanation
 
Pad Number
1–9 Pad number affected by the D Beam
Pad Velocity 1–127 Strength of the pad sound played by the D Beam controller
Pad Control Mode MOMENTARY, 
LATCH
Specifies how the D Beam will behave when it is obstructed.
 
MOMENTARY:
 
 The parameter will be on only while the D Beam is obstructed, and will turn off 
when you stop obstructing it.
 
LATCH:
 
 The parameter will alternately be switched on/off each time you obstruct the D Beam.
 
Parameter Value Explanation
 
Type CC01–31, 33–95, 
BEND UP, 
BEND DOWN, 
START/STOP, 
TAP TEMPO, 
ARP GRID, 
ARP DURATION, 
ARP MOTIF, 
ARP OCTAVE UP, 
ARP OCTAVE DOWN
Function controlled by the D Beam controller
 
CC01–31, 33–95:
 
 Controller numbers 1–31, 33–95
 
BEND UP:
 
 Controls the pitch as specified by the “Pitch Bend Range Up” setting (p. 41).
 
BEND DOWN:
 
 Controls the pitch as specified by the “Pitch Bend Range Down” setting (p. 41).
 
START/STOP:
 
 Starts/Stops the sequencer.
 
TAP TEMPO:
 
 Tap tempo (a tempo specified by the interval at which you move your hand over the 
D Beam controller).
 
ARP GRID:
 
 Arpeggio Grid
 
ARP DURATION:
 
 Duration of each arpeggiated note
 
ARP MOTIF:
 
 Arpeggio Motif
 
ARP OCTAVE UP:
 
 The range in which the arpeggio is sounded will rise in steps of an octave (max-
imum 3 octaves).
 
ARP OCTAVE DOWN:
 
 The range in which the arpeggio is sounded will lower in steps of an octave 
(maximum 3 octaves).
Range Min 0–127 Lower limit of the range of the D Beam controller
Range Max 0–127 Upper limit of the range of the D Beam controller.
By setting Range Max below Range Min you can invert the range of change.