MIDI Implementation
Address Parameter Name Sys.Ex.Value Meaning of Value
02H xxH 08H
09H
0AH
LEVEL
7EH 00H 00H,
7FH 79H 60H–00H 00H 00H–
00H 00H 64H
-INFdB, -80.0–0.0–10.0dB
02H xxH 0BH
FADE IN TIME 00H–64H 0.0–10.0sec
02H xxH 0CH
FADE OUT TIME 00H–64H 0.0–10.0sec
02H xxH 0DH
REPEAT 00H–01H OFF, ON
02H xxH 0EH
PAD MODE 00H–03H LATCH, PAUSE, REPLAY, MOMENTARY
02H xxH 0FH
PAD COLOR 00H–09H
WHITE, RED, GREEN, BLUE, YELLOW, MAGENTA, CYAN, DARK ORANGE,
TURQUOISE GREEN, PURPLE
02H xxH 10H
PLAYING MODE 00H–02H BGM, SE, SOLO
02H xxH 11H
12H
13H
14H
15H
OFFSET TIME
00H 00H 00H 00H 00H–
07H 7FH 7FH 7FH 7FH
0.0–214748364.7sec
* The actual maximum value depends on the length of the audio le.
À VIDEO PLAYER
Address Parameter Name Sys.Ex.Value Meaning of Value
02H 6DH 00H
01H
02H
03H
04H
START TIME
7FH 7FH 7FH 7FH 7FH–
00H 00H 00H 00H 00H–
07H 7FH 7FH 7FH 7FH
NONE, 0.0–2147483.647sec
* The actual maximum value depends on the length of the video le.
(Read Only)
02H 6DH 05H
06H
07H
08H
09H
END TIME
7FH 7FH 7FH 7FH 7FH–
00H 00H 00H 00H 00H–
07H 7FH 7FH 7FH 7FH
NONE, 0.0–2147483.647sec
* The actual maximum value depends on the length of the video le.
(Read Only)
02H 6DH
0AH
SKIP FORWARD TIME 00H–03H 1sec, 10sec, 30sec, 60sec
02H 6DH 0BH
SKIP BACKWARD TIME 00H–03H 1sec, 10sec, 30sec, 60sec
02H 6DH 0CH
REPEAT 00H–01H OFF, ON
À DATE&TIME
Address Parameter Name Sys.Ex.Value Meaning of Value
02H 6EH 00H
01H
(reserved)
02H 6EH 02H
DATE FORMAT 00H–02H MONTH/DAY/YEAR, DAY/MONTH/YEAR, YEAR/MONTH/DAY
02H 6EH 03H
CLOCK DISPLAY TYPE 00H–01H ANALOG, DIGITAL
02H 6EH 04H
CONFIGURE 00H–01H MANUAL, USING NTP
02H 6EH 05H
NTP SERVER 1 00H–7FH
:
: : :
02H 6EH 24H
NTP SERVER 32 00H–7FH
ÁCommand Area
À SCENE MEMORY
Address Parameter Name Sys.Ex.Value Meaning of Value
0AH 00H 00H
MEMORY LOAD TRIGGER 7FH–00H–1FH NONE, MEMORY 1–32 (write only)
0AH 00H 01H
MEMORY SAVE TRIGGER 7FH–00H–1FH NONE, MEMORY 1–32 (write only)
0AH 00H 02H
MEMORY INITIALIZE TRIGGER 7FH–00H–1FH NONE, MEMORY 1–32 (write only)
0AH 00H 03H
LOADED MEMORY NUMBER 7FH–00H–1FH LAST MEMORY, MEMORY 1–32 (read only)