EXCHANGING FILTER ELEMENT
WARNING
System is operating under pressure!
Opening the system when it is under pressure could
damage the maintenance unit and cause serious injury.
Ensure that the system is pressure-free before opening
the lter reservoir!
• Loosen the ring, and pull it off downwards.
• Loosen the protective guard, if present, and pull it off
downwards.
• Pull off the reservoir and the seal downwards.
• Unscrewthelterseat(a).
• Exchangethelterelement(b).
• Slidethelterunit(lterseatandlterelement)back
together.
• Connectthelterunittothelterandtightenitslightlyby
hand (c).
• Reinsert the container and the protective cage, if present,
in the reverse order.
c
a
b