Operating Instructions | Air Preparation Products
7
SEMI- AND FULLY AUTOMATIC
CONDENSATE DRAIN
CAUTION
The condensate could cause damage to the
compressed air system!
Condensate is drained in semi-automatic drains only when
the reservoir is un a pressure-free state. Over long periods
of operation, the condensate can exceed maximum capa-
city and get into the compressed air system. This could
damage the compressed air system.
Regularly check the capacity of the collecting container.
. If the condensate reaches maximum capacity (b), drain
the condensate manually.
Do not blow off the condensate uncontrollably into the
environment.
SEMI-AUTOMATIC CONDENSATE DRAIN (I)
The semi-automatic condensate drain closes at a pressure
> 1.5 bar and opens at an operating pressure < 1.5 bar.
FULLY AUTOMATIC CONDENSATE DRAIN (II)
“Normally open“ conguration:
In the „normally open“ conguration, the condensate drain
closes at a pressure > 1.5 bar and opens at an operating
pressure < 1.5 bar. The valve opens automatically as soon
as the oater reaches the highest point and closes again
when the oater reaches the fowest point.
“Normally closed“ conguration:
The condensate drain is closed regardless of the operating
pressure. The valve opens automatically as soon as the
oater reaches the highest point and closes again when the
oater reaches the lowest point