Operating Instructions | Air Preparation Products
8
SETTING THE AUTOMATIC MODE
For semi-automatic condensate drain (I)
Open drain screw by turning it all the way to the left. You may
leave the screw one turn deep in the thread or remove it com-
pletely.
For fully automatic condensate drain (II)
Turn drain screw to right as far as it will go. You may leave
the screw one turn deep in the thread or remove it comple-
tely.
Note: If the screw is srewed in completely, the automatic
drainage is blocked.
DRAINING CONDENSATE MANUALLY
The condensate can also be drained manually.
For semi-automatic condensate drain (I)
Turn drain screw (a) all the way to the right (closed
position).
Turn drain screw (a) a few rotations to the left until
condensate ows out.
For fully automatic condensate drain (II)
Turn drain screw (a) to left.
MOUNTED CONDENSATE DRAIN
(MOUNTING HOSES)
The condensate can also be drained directly using a hose.
For semi-automatic condensate drain (I)
Remove drain screw (a).
Screw the hose (b) into the container‘s connection
thread G 1/8.
For fully automatic condensate drain (II)
Screw the hose (b) into the container‘s connection
thread G 1/8.
+
-
I.
+
-
II.
II.I.
a
b
b