9
•Checkaccessibilityoftheoperatingprocedures.
•Checkaccessibilityandreadabilityofalllabels.
•Checktheratedloadcapacityofthelift.
•Examineallstructuralcomponentsincludingwelds.
•Checkelectricalcordsforinsulationdamage.
•Checkuidlevel.
•Checktheliftcontrolsforfunction.
•Checkforproperfunctionofswingarmrestraints.
•Checkallfasteningdevicesfortightnessincludingooranchorbolts.
•Checkexposedsurfacesandedges.
•Operatetheliftandchecktheoperationofthepositivestopandtheliftsafetylatches.
•Checkforproperoperationofadapters.
•Witharepresentativevehicleonthelift,checktheloweringspeed(nottoexceed0.15m/s).
•Checktheoperationofthesynchronizationorequalizationsystemsothatbothsidesraiseandlowerequally.
•*Check the function of overhead switch.
•Checkallaccessiblepiping,tubing,hose,valvesandttings.Reviewliftoilconsumptionrecords.
•*Operate lift through full excursion and observe.
•Withliftloaded,stoptheliftatmidpointoftravelandobservefordriftingdownandhydraulicleaks.
•Checkwithoperatortoascertainanyunusualoperatingcharacteristics.
*Perform check with and without a vehicle representative load.
INSPECTION POINTS
REPAIR MAINTENANCE
(MAINTENANCE AUTHORIZED BY QUALIFIED SERVICE REPRESENTATIVE ONLY)
Asidefromtheroutinechecksthatarestatedunder"OperatorMaintenance",thefollowingannualinspectionistobeperformed
andarecordofthisinspectionpermanentlyretainedonsite.Alldecienciesaretobecorrectedbytheproperauthorized
personnel.
ANNUAL INSPECTION
(PERFORMED BY AUTHORIZED PERSONNEL)
• Lockoutallenergysourcesbeforebeginninganyrepairs.
• DONOTmodifytheliftinanymannerwithouttheprior
writtenconsentofthemanufacturer.
• Ifelectricalproblemsdevelop,makerepairsaccordingto
localelectricalcodes.UsegenuineRotaryLiftpartswhen
replacementisnecessary.
• ReplacewornpartsasrequiredwithgenuineRotaryparts.
• Adjustequalizercabletensionperliftinstallationinstructions.
• Monthly: Lubricate locking latch shafts. Push latch handle
severaltimesforoiltopenetratejoints.