EasyManua.ls Logo

Rotary SM14 - Lift Not Raising Off Latches

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Fig. 12a
Fig. 12b
Run nut down just
below impact section
of bolt. Drive anchor
into hole until nut and washer
contact base.
Clean hole.Drill holes using carbide
tipped masonry drill bit per
ANSI B212.15-1994 (R2000)
Tighten nut with
Torque wrench to
60 ft.-lbs.
CONCRETE AND ANCHORING REQUIREMENTS
STANDARD ANSI/ALI ALCTV IBC 2006, 2009, 2012 SEISMIC
Minimum Floor Thick-
ness
4-1/4 INCHES 4-3/8 INCHES 5 INCHES
Varies by location consult
with your structural engineer
and manufacturer’s repre-
sentative.
Anchor Hilti Kwik Bolt III*
5/8" x 4-1/4"
Hilti HIT-HY
150MAX-SD
Adhesive; Hilti
HIT-HY 150 MAX
Adhesive; HILTI
HIT-RE 500-SD
Adhesive
Hilti Kwik Bolt III
5/8" x 6"
Minimum Concrete
Strength
3000 PSI 3000 PSI 3000 PSI
Minimum Anchor Em-
bedment
2-3/4 INCHES 3-1/8 INCHES 3-1/8 INCHES
Minimum Distance to
Concrete Edge, Crack,
Expansion Joint, Aban-
danoned Anchor Hole
4-1/2 INCHES 3-1/8 INCHES 2-1/4 INCHES
*The supplied concrete fasteners meet the criteria of the American National Standard
“Automotive Lifts - Safety Requirements for Construction, Testing, and Validation” ANSI/ALI ALCTV-2011, and the lift
owner is responsible for all charges related to any additional anchoring requirements as specified by local codes.
Contact customer service for further information at: 800.445.5438