Concrete and Anchoring:
If you are installing a seismic lift, consult with your
structural engineer and manufacturer’s representative for
concrete and anchoring requirements (varies by location).
Fig. 4 and the below table apply to non-seismic lifts only.
Fig. 4
7-10K 2-Post Lift Anchor Installation Reference Guide
Anchor: Min
Concrete
Thickness
Min Edge
Distance
Min Anchor
Embedment
Installation Anchor
Torque ft-lbs
Min Concrete PSI
Strength - For All
Standards
Concrete pad
Size If Concrete
Does Not Meet
Requirements
Maintenance
Torque
Values
SEISMIC
Hilti Kwik
Bolt III (3/4" x
5-1/2")
4-1/4"
(108mm)
3-3/8"
(86mm)
3-1/4" (83mm) 110
(149Nm)
3000
(20684 kPa)
4'x4'x6"
(1219 x 1219 x
152mm)
65 ft-lbs
(88Nm)
Varies by
location consult
with your
structural engineer
and manufacturer’s
representative.
Hilti HY200
(with HAS
threaded rod)
6-7/16"
(164mm)
1-3/4"
(45mm)
4-1/2"
(115mm)
100 (149Nm) / less
than 3-3/4" (95mm)
edge distance use
Torque Value of 30
ft-lbs (41Nm)
3000
(20684 kPa)
4'x4'x6"
(1219 x 1219 x
152mm)
N/A
Hilti HY200
(with HAS
threaded rod)
5-1/4"
(134mm)
3" (77mm) 3-1/2" (89mm) 100 (149Nm) / less
than 3-3/4" (95mm)
edge distance use
Torque Value of 30
ft-lbs (41Nm)
3000
(20684 kPa)
4'x4'x6"
(1219 x 1219 x
152mm)
N/A
*The supplied concrete fasteners meet the criteria of the American National Standard
“Automotive Lifts - Safety Requirements for Construction, Testing, and Validation” ANSI/ALI ALCTV-2011,
and the lift owner is responsible for all charges related to any additional anchoring requirements as
specified by local codes. Contact customer service for further information at: 800.640.5438
Run nut down just below impact
section of bolt. Drive anchor
into hole until nut and washer
contact base.
Drill holes using 3/4” carbide
tipped masonry drill bit per
ANSI B212.15-1994 (R2000).
Construction dust collected
per OSHA 29 CFR 1926.1153.
Tighten nut with Torque
wrench to 110 ft.-lbs.
(149 Nm).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotary SPOA10 700 Series and is the answer not in the manual?

Rotary SPOA10 700 Series Specifications

General IconGeneral
Capacity10, 000 lbs
Drive-Thru Clearance88.625 inches
Motor2 HP
Voltage208-230V
Lifting Capacity10, 000 lbs
Load Capacity10, 000 lbs
Power Supply208-230V