Effectivity: 912 Series BRP-Powertrain page 4-6
OM Edition 2 / Rev. 1 November 01/2010
d04946.fm
Oil level Oil level is increasing
Cold engine start Engine hard to start at low temperature
Possible cause Remedy
Oil too cold during engine op-
eration.
cover oil cooler surface, maintain the oil
temperature prescribed.
Possible cause Remedy
Starting speed too low. preheat engine.
Low charge battery. fit fully charged battery.
High oil pressure. At cold start a pressure reading of up to
around 7 bar (102 psi) does not indicate
a malfunction.
Oil pressure too low after cold
start.
Too much resistance in the oil suction
tube at low temperatures. Stop engine
and preheat oil.
At oil pressure reading too low than 1
bar oils with lower viscosity are to be
used.
See SI-912-016, current issue.
NOTE:
Oil pressure must be measured at idle at an oil
temperature of minimum 50 °C (120 °F).
Be sure the oil pressure does not go below
minimum at idle.