Effectivity: 912 Serie
Edition 4 / Rev. 0
BRP-Rotax Page 3-11
November 01/2016
ATTENTION
Fuels containing alcohol always carry a small amount of water
in solution. In case of temperature changes or increase of alco-
hol content, water or a mixture of alcohol and water may settle
and could cause troubles.
Water in fuel will accumulate at the lower parts of the fuel sys-
tem and leads to freezing of fuel lines, filters or jets.
Remedy
Use non-contaminated fuel (filtered through suede)
Generously sized water separators
Fuel lines routing inclined
Prevent condensation of humidity, i. e avoid temperature dif-
ferences between aircraft and fuel