  • G
    Gina HerreraAug 13, 2025
    What to do if Roxell FLEX-AUGER FA 125 transport system does not run?
    • B
      Beverly BrownAug 14, 2025
      If the transport system isn't running, several issues could be the cause. First, check the fuses and/or reset the circuit breakers, and inspect the cut-off switches and current lead to the house, repairing if necessary. A defective level switch could also be the problem; ensure it's correctly installed, look for feed bridging in the control unit, and replace the switch if needed. Similarly, check the operation of the safety switch in the control unit and replace it if defective. Lastly, a defective motor could be the cause, requiring replacement.
  • K
    kswansonAug 17, 2025
    Why does my Roxell Farm Equipment motor overload after running for a short while?
    • P
      Patrick TranAug 17, 2025
      If the motor overloads quickly, several factors could be at play. It might be the wrong motor, so check the motor power and replace it if necessary. Low voltage can also cause this; inspect the current supply to the motor and use wires with the correct diameter for the connection. A foreign object in the auger can cause the motor to stall; carefully disconnect the auger, remove the object, and clean the auger and tubes, also checking the feed's fat content and moisture percentage. Ensure the motor isn't running in reverse by verifying the motor shaft turns clockwise and checking the auger for damages. Finally, the motor itself might be overheating, in which case, replace it.
  • D
    darrylevansAug 21, 2025
    What to do if Roxell FLEX-AUGER FA 125 transport system short cycles continually?
    • C
      Corey SmithAug 21, 2025
      If the transport system cycles too frequently, the level switch might not be correctly positioned in the 100kg hopper; adjust its position. Alternatively, a sensor in the tube could be the issue; consider using a VC11 or VC12 sensor if necessary.
  • J
    Julie GuzmanAug 25, 2025
    What to do if Roxell Farm Equipment motor runs, but auger does not turn?
    • P
      Patrick RoseAug 26, 2025
      If the motor is running but the auger isn't turning, the issue is likely a broken bolt or a worn-out set screw in the drive shaft. Replace the bolt or set screw to resolve this.
  • A
    Allison WrightAug 28, 2025
    Why does Roxell FLEX-AUGER FA 125 Farm Equipment auger run erratically?
    • P
      Paul SmithAug 28, 2025
      An erratic auger operation can stem from several causes. The boot bearing might be jammed or worn out, requiring replacement. The auger might be too long; shorten it, close all outlets, remove the bearing and anchor, disconnect the auger, run the system briefly, cut the auger at the rear end of the boot, and reinstall. Poor tube suspension or too many elbows can also contribute; add more suspension points, adjust the height, and reduce the number of elbows. Lastly, a kinked or poorly brazed auger scraping along the tubes could be the problem; refer to the auger brazing instructions.
  • M
    matthew43Sep 1, 2025
    What causes feed bridging in the extension boot of Roxell FLEX-AUGER FA 125 Farm Equipment?
    • D
      Dennis RiveraSep 1, 2025
      Feed bridging in the extension boot can occur if there isn't enough feed drop from the last outlet before the extension boot; ensure a 100% feed drop. Additionally, the time set on the relay might be too short; consult the instructions for proper settings.
  • A
    Adriana FranklinSep 5, 2025
    Why do elbows wear out on Roxell FLEX-AUGER FA 125 Farm Equipment?
    • K
      kingcurtisSep 5, 2025
      Elbows wear out because the auger is either too short or too long. Adjust the auger length or install an extension boot if necessary.
  • M
    Monica HallSep 9, 2025
    What causes the second part (past the extension boot) of Roxell Farm Equipment not to start?
    • M
      Marissa BrownSep 9, 2025
      If the section past the extension boot isn't starting, the level switch on the first part may be defective. Check the operation of the level switch and replace it if needed.

Summary

Part I: Instructions for the User

General Safety Rules

Critical safety instructions for installation and operation, highlighting potential hazards and precautions.

Operators Guide

Instructions on system operation, feed handling, and using specific components like the slide valve.

Maintenance Instructions

Schedule and procedures for routine power unit, suspension, sensor, and line maintenance.

Trouble Shooting Guide

Identifies common problems, their causes, and corrective actions for the transport system and motor.

Part III: Installation Instructions

General Safety Rules for Installation

Critical safety instructions for installation, emphasizing careful handling and secure fixation of components.

Installation Procedures for Major Components

Step-by-step instructions for installing control units, extension boots, and connecting the transport system.

Tube and Auger Installation

Procedures for installing tubes, making drop holes, and inserting the auger into the system.

Electrical Diagrams and Motor Protection

Electrical diagrams for various configurations and essential information on motor protection.

Roxell FLEX-AUGER FA 125 Specifications

General IconGeneral
BrandRoxell
ModelFLEX-AUGER FA 125
CategoryFarm Equipment
LanguageEnglish

Related product manuals