    What to do if Roxell FLEX-AUGER FA 75 Farm Equipment transport system does not run?
    • S
      stephaniejonesAug 14, 2025
      If the transport system isn't running, several issues could be the cause. First, check the fuses and/or reset the circuit breakers, and inspect the cut-off switches and current lead to the house, repairing if necessary. A defective level switch could also be the problem; ensure it's correctly installed, look for feed bridging in the control unit, and replace the switch if needed. Similarly, check the operation of the safety switch in the control unit and replace it if defective. Lastly, a defective motor could be the cause, requiring replacement.
  • C
    Cameron CarterAug 17, 2025
    Why does my Roxell FLEX-AUGER FA 75 Farm Equipment motor overload after running for a short while?
    • L
      Lisa BuckleyAug 17, 2025
      If the motor overloads quickly, several factors could be at play. It might be the wrong motor, so check the motor power and replace it if necessary. Low voltage can also cause this; inspect the current supply to the motor and use wires with the correct diameter for the connection. A foreign object in the auger can cause the motor to stall; carefully disconnect the auger, remove the object, and clean the auger and tubes, also checking the feed's fat content and moisture percentage. Ensure the motor isn't running in reverse by verifying the motor shaft turns clockwise and checking the auger for damages. Finally, the motor itself might be overheating, in which case, replace it.
  • R
    robert42Aug 21, 2025
    What to do if Roxell FLEX-AUGER FA 75 transport system short cycles continually?
    • G
      Gregory JohnsonAug 21, 2025
      If the transport system cycles too frequently, the level switch might not be correctly positioned in the 100kg hopper; adjust its position. Alternatively, a sensor in the tube could be the issue; consider using a VC11 or VC12 sensor if necessary.
  • C
    Chris ReynoldsAug 25, 2025
    What to do if Roxell Farm Equipment motor runs, but auger does not turn?
    • T
      travis33Aug 26, 2025
      If the motor is running but the auger isn't turning, the issue is likely a broken bolt or a worn-out set screw in the drive shaft. Replace the bolt or set screw to resolve this.
  • T
    Tyler BaileyAug 28, 2025
    Why does Roxell FLEX-AUGER FA 75 Farm Equipment auger run erratically?
    • C
      Christine Thompson MDAug 28, 2025
      An erratic auger operation can stem from several causes. The boot bearing might be jammed or worn out, requiring replacement. The auger might be too long; shorten it, close all outlets, remove the bearing and anchor, disconnect the auger, run the system briefly, cut the auger at the rear end of the boot, and reinstall. Poor tube suspension or too many elbows can also contribute; add more suspension points, adjust the height, and reduce the number of elbows. Lastly, a kinked or poorly brazed auger scraping along the tubes could be the problem; refer to the auger brazing instructions.
  • M
    Michelle HayesSep 1, 2025
    What causes feed bridging in the extension boot of Roxell FLEX-AUGER FA 75?
    • S
      Sean GonzalezSep 1, 2025
      Feed bridging in the extension boot can occur if there isn't enough feed drop from the last outlet before the extension boot; ensure a 100% feed drop. Additionally, the time set on the relay might be too short; consult the instructions for proper settings.
  • E
    Erika WilliamsSep 5, 2025
    Why do elbows wear out on Roxell FLEX-AUGER FA 75?
    • C
      Christine HoffmanSep 5, 2025
      Elbows wear out because the auger is either too short or too long. Adjust the auger length or install an extension boot if necessary.
  • J
    Joe HinesSep 8, 2025
    What causes the second part (past the extension boot) of Roxell Farm Equipment not to start?
    • B
      Brent MorganSep 8, 2025
      If the section past the extension boot isn't starting, the level switch on the first part may be defective. Check the operation of the level switch and replace it if needed.

Summary

PART I: INSTRUCTIONS FOR THE USER

GENERAL SAFETY RULES

Essential safety guidelines for operating and installing the Flex-Auger system.

OPERATORS GUIDE

Instructions on the correct use and daily operation of the Flex-Auger system.

MAINTENANCE INSTRUCTIONS

Procedures for regular inspection and upkeep to ensure system longevity and performance.

TROUBLE SHOOTING GUIDE

Common problems, their causes, and corrective actions for the Flex-Auger system.

PART II: COMPONENTS

POWER UNIT

Detailed illustration and part numbers for the motor and gearbox assembly.

PART III: INSTALLATION INSTRUCTIONS

GENERAL SAFETY RULES FOR INSTALLATION

Critical safety precautions to follow before and during system installation.

TOOLS REQUIRED FOR INSTALLATION

List and illustrations of essential tools needed for Flex-Auger installation.

DISTANCE BETWEEN SUSPENSION POINTS

Recommendations for spacing and load capacity of tube support points.

CONTROL UNIT ASSEMBLY AND INSTALLATION

Step-by-step instructions for assembling and mounting the control unit.

TO INSTALL THE TUBES

Instructions on how to connect the auger tubes to the anchor weldments.

TO INSTALL THE AUGER

Procedures for preparing and inserting the auger into the tubes.

TO CONNECT THE AUGER

Steps for connecting the auger to the power unit and boot.

Roxell FLEX-AUGER FA 75 Specifications

General IconGeneral
ModelFLEX-AUGER FA 75
CategoryFarm Equipment
Tube Diameter75 mm
MaterialGalvanized Steel
TypeFlexible Auger
Motor Power1.5 kW
ApplicationTransportation of feed in farms