FLEX-AUGER - INSTRUCTIONS FOR THE USER
ROXELL - 031- 0516
I-5
ATTENTION : Contact ROXELL your supplier for professional advice when using following feeds :
CCM (Corn Cob Mix) - Feed mixed with CCM - Soya - Soya lumps - Wet feed.
Without explicite authorization, all our warranties will expire and no claims will be accepted.
Also contact Roxell if you want to use strongly grating feeds like hen feed etc...
MAINTENANCE INSTRUCTIONS
Switch off the main switch first.
Use personal protective equipment.
DANGER
3-monthly
6-monthly
Yearly
ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON.
1. Power unit
- Make fan dust-free X
- Check possible damages to electrical wiring X
2. Suspension
- Check suspension of tubes and motors X
3. Sensors/switches
- Check operation of safety switch X
- Check electrical wiring X
4. Lines
- Check screws and bolts in the system after the first month and after
each batch. Tighten if necessary.
X
- Keep tubes level. X
- Remove all feed from the system when t he system will be out of use for a
period.