030-051603000031
*03000031*
Original use and assembly guide
Use and Assembly Guide
Instructions
for the user
Components Installation
instructions
EN ENGLISH

Table of Contents

Questions and Answers

  • S
    Steven Hale DDSAug 12, 2025
    What to do if Roxell Farm Equipment transport system does not run?
    • J
      Jennifer OliverAug 12, 2025
      If the transport system isn't running, several issues could be the cause. First, check the fuses and/or reset the circuit breakers, and inspect the cut-off switches and current lead to the house, repairing if necessary. A defective level switch could also be the problem; ensure it's correctly installed, look for feed bridging in the control unit, and replace the switch if needed. Similarly, check the operation of the safety switch in the control unit and replace it if defective. Lastly, a defective motor could be the cause, requiring replacement.
  • M
    Michael MartinezAug 16, 2025
    Why does my Roxell Farm Equipment motor overload after running for a short while?
    • M
      Mr. Christopher MuellerAug 16, 2025
      If the motor overloads quickly, several factors could be at play. It might be the wrong motor, so check the motor power and replace it if necessary. Low voltage can also cause this; inspect the current supply to the motor and use wires with the correct diameter for the connection. A foreign object in the auger can cause the motor to stall; carefully disconnect the auger, remove the object, and clean the auger and tubes, also checking the feed's fat content and moisture percentage. Ensure the motor isn't running in reverse by verifying the motor shaft turns clockwise and checking the auger for damages. Finally, the motor itself might be overheating, in which case, replace it.
  • M
    margarethughesAug 19, 2025
    What to do if Roxell FLEX-AUGER FA 90 Farm Equipment transport system short cycles continually?
    • S
      Stacey LewisAug 19, 2025
      If the transport system cycles too frequently, the level switch might not be correctly positioned in the 100kg hopper; adjust its position. Alternatively, a sensor in the tube could be the issue; consider using a VC11 or VC12 sensor if necessary.
  • J
    Jeffrey CooperAug 23, 2025
    What to do if Roxell FLEX-AUGER FA 90 Farm Equipment motor runs, but auger does not turn?
    • J
      Jonathan LongAug 25, 2025
      If the motor is running but the auger isn't turning, the issue is likely a broken bolt or a worn-out set screw in the drive shaft. Replace the bolt or set screw to resolve this.
  • D
    Denise GuerreroAug 27, 2025
    Why does Roxell Farm Equipment auger run erratically?
    • L
      Lance HartAug 27, 2025
      An erratic auger operation can stem from several causes. The boot bearing might be jammed or worn out, requiring replacement. The auger might be too long; shorten it, close all outlets, remove the bearing and anchor, disconnect the auger, run the system briefly, cut the auger at the rear end of the boot, and reinstall. Poor tube suspension or too many elbows can also contribute; add more suspension points, adjust the height, and reduce the number of elbows. Lastly, a kinked or poorly brazed auger scraping along the tubes could be the problem; refer to the auger brazing instructions.
  • A
    amartinAug 31, 2025
    What causes feed bridging in the extension boot of Roxell FLEX-AUGER FA 90?
    • C
      Christopher MyersAug 31, 2025
      Feed bridging in the extension boot can occur if there isn't enough feed drop from the last outlet before the extension boot; ensure a 100% feed drop. Additionally, the time set on the relay might be too short; consult the instructions for proper settings.
  • C
    Christopher SalinasSep 4, 2025
    Why do elbows wear out on Roxell FLEX-AUGER FA 90 Farm Equipment?
    • J
      justin21Sep 4, 2025
      Elbows wear out because the auger is either too short or too long. Adjust the auger length or install an extension boot if necessary.
  • J
    Jeffrey BrownSep 7, 2025
    What causes the second part (past the extension boot) of Roxell FLEX-AUGER FA 90 not to start?
    • T
      Thomas RomeroSep 7, 2025
      If the section past the extension boot isn't starting, the level switch on the first part may be defective. Check the operation of the level switch and replace it if needed.

Summary

General Information

Information About Residual Risks and Safety Signs

Safety Signs and Danger Levels

Explains DANGER, WARNING, and CAUTION levels and symbols.

Dismantling and Safety Procedures

Lock Out Tag Out Procedure

Procedures for safely de-energizing equipment during maintenance.

Use Personal Protective Equipment

Emphasizes wearing personal protective equipment like gloves and dust masks.

Electrical Equipment Safety

Safety and handling instructions for electrical components and control panels.

Part I: Instructions for the User

Operators Guide

Instructions on how to operate the Flex-Auger system correctly and efficiently.

Maintenance Instructions

Guidelines for performing regular maintenance tasks on the Flex-Auger system.

Trouble Shooting Guide

Common problems and their solutions for the Flex-Auger system.

Part III: Installation Instructions

General Safety Rules for Installation

Critical safety instructions to be followed before and during system installation.

Installing Suspension Points

Detailed instructions on how to properly install suspension points.

Control Unit Assembly and Installation

Step-by-step instructions for assembling and installing the control unit.

Multiple Control Unit Installation

Procedures for installing multiple control units in a system.

Extension Boot Assembly and Installation

Instructions for assembling and installing the extension boot.

Making Drop Holes in Tubes

Guidance on creating the correct drop holes in the system tubes.

Installing the Outlets

Procedures for installing the various outlet components.

Installing the Automatic Outlet

Step-by-step guide for installing the automatic outlet.

Connecting Transport System to Bin

Guidance on connecting the transport system to the feed bin.

Sealing Tube Connections

Emphasizes using sealants for watertight tube connections outside the house.

Installing the Auger

Detailed instructions for installing the auger into the system.

Auger Brazing Procedures

Procedures and recommendations for brazing auger joints.

Connecting the Auger

Steps for connecting the auger to the power unit and the boot.

Installing Drop Tubes

Instructions for installing the drop tubes, including telescopical and flexible types.

Installing the Tubes

Detailed steps for installing the various tubes and connection pieces.

Electricity Safety Precautions

Critical safety warnings and instructions regarding electrical connections.

Motor Protection Settings

Guidance on setting and verifying motor protection parameters.

Roxell FLEX-AUGER FA 90 Specifications

General IconGeneral
ModelFLEX-AUGER FA 90
CategoryFarm Equipment
Outer Diameter90 mm
LengthCustomizable
Power RequirementVaries based on configuration
WeightVaries based on length and configuration
TypeFlexible Auger Conveyor

Related product manuals