ROXELL - 031 - 0516
FLEX-AUGER - INSTALLATION INSTRUCTIONS
III-54
FIGURE 119.
Do not yet connect the auger in the intake boot A (leave some 20cm outside the boot).
Open Feed Bin valve A and start the Flex Auger
Let the Flex-Auger run untill the feed comes out at the control unit. Stop the Flex-Auger and mark the au-
ger (M1).
Close feed bin valve A and let the Flex-Auger run empty.
Open feed bin valve B and start the Flex-Auger again. Let the auger run until the feed comes out at the
control unit. Stop the Flex auger and mark the auger (M2).
Cut the auger in the middle between M1 and M2 and connect in the intake boot with the anchor and bear-
ing assembly.
AUGER STRETCHING (STRAIGHT THROUGH TANDEM)