EP Series User Manual
38
Motor type setting register
0: Two-phase stepper motor
1: Three-phase stepper motor
Motor running mode setting register
0: Open-loop running
1: Servo mode one
2: Servo mode two
Motor direction inversion setting register
0: Default running direction
1: Reverse the running direction of the motor
3.3.5. Open-loop running parameter settings [24~29]
Table 3-12 Register details [24-29]
Open-loop running current
Sine peak value when the driver is running in
open-loop. Unit: mA
Standby Current Percentage
Set the current as a percentage of the
running current when the driver enters the
standby state in open-loop running mode.
Unit: %
Standby time setting
Set the time for the driver to enter the
standby state after the pulse stops for a
certain period of time when the driver is
running in open-loop. Unit: ms
Pulse command filter
For smoothing pulse commands (including
internal and external pulses),
Filter time = set value * 50us
Encoder current position (number of pulses)