FGS-2824 User Manual
Publication date: July, 2005
Revision A1
194
port
clear counter
Syntax:
clear counter
Description:
To clear all ports’ counter (include simple and detail port counter) information.
Argument:
None
Possible value:
None
Example:
FGS-2824 (port)# clear counter
disable flow-control
Syntax:
disable flow-control <range>
Description:
To disable the flow control function of the port.
Argument:
<range>: syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 ~ 24
Example:
FGS-2824 (port)# disable flow-control 6
disable state
Syntax:
disable state <range>
Description:
To disable the communication capability of the port.
Argument:
<range>: syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 ~ 24
Example:
FGS-2824 (port)# disable state 12