RuggedCom RuggedSwitch RS900 Family - Table 17 - Fiber Optic Port Specifications

RuggedCom RuggedSwitch RS900 Family
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS900 Family Installation Guide
6.4.3 Fiber Optic Ethernet Port Specifications
Order
Code
Speed
Standa
rd
Mode /
Connector
Tx
(nm)
Cable
Type
(um)
Tx
min
(dBm)
Tx
max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Typical
Distance
(km)
Power
Budget
(dB)
MJ 100FX MM/MTRJ 1300 50/125 -22.5 -14 -33.5 -14 2 11
62.5/125 -19 -14 -33.5 -14 2 14.5
MC 100FX MM/SC 1300 50/125 -22.5 -14 -33.9 -14 2 11.4
62.5/125 -19 -14 -33.9 -14 2 14.9
MT 100FX MM/ST 1300 50/125 -22.5 -14 -33.9 -14 2 11.4
62.5/125 -19 -14 -33.9 -14 2 14.9
ML 100FX MM/LC 1310 62.5/125 -19 -14 -32 -14 2 13
T2 100FX SM/ST 1310 9/125 -15 -7 -34 -3 20 19
L2 100FX SM/LC 1300 9/125 -15 -8 -38 -3 20 23
C2 100FX SM/SC 1300 9/125 -15 -8 -31 -7 20 16
L5 100FX SM/LC 1310 9/125 -5 0 -35 -3 50 30
C5 100FX SM/SC 1310 9/125 -5 0 -34 -3 50 29
L9 100FX SM/LC 1310 9/125 0 5 -37 0 90 37
C9 100FX SM/SC 1310 9/125 5 0 -37 0 90 42
Table 17 - Fiber Optic Port Specifications
NOTES:
1. All values listed are average values
2. To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3
dBm.
3. Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.