MODEL 82602-F79A-LCD/82602B-F79B-LCD/82604-F82A-LCD/82604B-F82B-LCD
3
No hard water bypass refers to the control valve no water pass when
valve in regeneration. Model: A for no hard water bypass (No raw water
flow out from outlet when in regeneration process); B for with hard water
bypass. (With raw water flow out from outlet when in regeneration process)
With partial bypass function
Service time, by adjusting bypass screw can let part of raw water flow
into the outlet without being softened.
Down-flow regeneration, up-flow regeneration and filter can be
implemented with a valve.
By program selection to choose following modes
Down-flow
Regeneration,
Meter
Delayed
Down-flow regeneration, regenerate on the day
although the available volume of treated water
drops to zero (0). Regeneration starts at the
regeneration time.
Down-flow
Regeneration,
Meter
Immediate
Down-flow regeneration, regenerate when the
available volume of treated water drops to zero (0).
Down-flow
Regeneration,
Intelligent
Meter Type
Down-flow regeneration, regenerate starts at the
regeneration time of the current day when the
available volume of treated water less than the
average water consumption of last 7 days.
Up-flow
Regeneration,
Meter
Delayed
Up-flow regeneration, regenerate starts at the
regeneration time although the available volume
water of treated water drops to zero (0).
Regeneration starts at the regeneration time.
Up-flow
Regeneration,
Meter
Immediate
Up-flow regeneration, regenerate when the
available volume of treated water drops to zero (0).
Up-flow
Regeneration,
Intelligent
Meter Type
Up-flow regeneration, regeneration starts at the
regeneration time of the current day when the
available volume of treated water less than the
average water consumption of last 7 days.
Filter type, filter when the service days or available