9 Maintenance
BA.GB.12-27409-05-07-FTA-jr
RUTHMANN-Steiger
®
TB270
9-3
safety devices must be re-installed properly.
Attention!
It must always be avoided that dirt or other pollutions
can get into the hydraulic system. Cleanness is of par-
amount importance during maintenance of the hydraulic
system.
When working especially at the hydraulic system only
use fibre-free cloths.
When handling with oil you have to take care that no oil can
get into the earth or into the sewerage system.
Used oil, used grease and oily or greasy cloths respectively
must be disposed in a way which is not harmful to the envi-
ronment. Biological oils and mineral oils must be disposed
separately. For reasons of disposal and the necessary ex-
pert knowledge, we recommend letting the maintenance and
repair work carried out by the Ruthmann-after-sales-service
or by personnel authorized by us.
Note
If regulations and safety data are not observed and result in
damage any warranty claim expires.
Apart from the below explanations especially the safety in-
structions of chapter 1.2 must be observed.
For certain maintenance work (e.g. function test) operation of the Ruth-
mann-Steiger becomes necessary. In these cases special care should be
taken. After finishing this work the Ruthmann-Steiger must again be taken
out of operation and secured accordingly for further maintenance work.
Sealed constructional components must only be opened by Ruthmann-
after-sales-service. Inspection, maintenance and repair work at these con-
structional components may only be carried out by the Ruthmann-after-
sales-service or by personnel authorized by us.