9 Maintenance
BA.GB.12-27409-05-07-FTA-jr
RUTHMANN-Steiger
®
TB270
9-57
knowledge and tools we recommend letting have the battery
and battery acid changed by the Ruthmann-after-sales-
service or personnel authorized by us.
Vehicle battery
Check oil level of the battery liquid.
Check charging condition of battery. Re-charge battery if necessary (no
rapid charge). The capacity will decrease with sinking temperature. A
considerably cooled down battery only has a fraction of its performance.
Therefore re-charge more often during winter time.
Clean battery if necessary. Keep battery poles clean. Grease slightly the
pole binders (connecting poles) by means of an acid-free and acidproof
grease (e.g. vaseline).
When changing the battery, please duly observe the operating and
maintenance instructions of the manufacturer of the battery.
Button cells of the computer system
We recommend letting the rechargeable button cells changed after 6
years. A change is absolutely necessary after 8 years. E.g. the change
can be carried out during the regular check (check by an expert).