Chapter 2 Names
and
Functions
I····Monitorindicatio#'::l
@ @
0
ct>
ct>
0
(iJ
(iJ
0 0
~
@·o~
@·o~
\: . \: .
0 0
I
ee
1
l
c6
09'~
E~
FSQG~H~
I_Q
J~
rr
A.
Safety device operation indication
( • Safety Operation Edition- 18)
B. Unit indication lamp
When the dampening solution in the water fountain
is not at the proper level, the water roller cleaning
lever is at the
~position,
or a blanket jam occurs,
the lamp for that unit will light.
C. [I]
Water
warning lamp
When the dampening solution in the water fountain
on the first unit or second unit
is
not at the proper
level, this lamp will light.
When this lamp lights, the metering roller will not
rotate. Also the paper feed button cannot go ON.
When supplying the dampening solution into the
water fountain, the lamp will go off.
D.
~Water
roller cleaning lever ON detector
lamp
When the water roller cleaning lever is at the
~
position on the first unit
or
second unit, this lamp
will light.
When this lamp lights, printing cannot be done.
When setting the water roller cleaning lever at the
~
position, the lamp will go off.
E.
~Blanket
jam
detector lamp
When a sheet
of
paper
is
jammed on the blanket on
the first unit
or
second unit, the press will stop. At
this time, a buzzer will sound and the lamp will light.
After removing the jammed paper, the lamp will go
off.
Introduction Edition- 16
(Note) When more than 2 conditions in (C) through (E)
in the previous column occur, the trouble will be
indicated by one lamp lighted and the other lamp
flickering. When this occurs, first correct the
trouble indicated by the lamp that lights. After
that correction, the lamp that is flickering will
change to lighting. Continuously,
correct
the
trouble indicated by that lamp.
Example)
If
the
trouble
following occurs,
....
First unit The dampening solution in the water
fountain
is
not at the proper level.
Second unit ... The water roller cleaning lever is at
the
~position.
The dampening solution in the water
fountain is not at the proper level.
~0.
Tr
2 1
The water roller cleaning lever
is
at
0
the
~position.
The dampening solution in the water
0
0
fountain
is
not at the proper level.
Lamp indication
and
trouble correcting procedures
,u;
... Light
,'''~
... Flicker
1
Set the water roller cleaning lever on the second unit
at the
~
position.
Supply the dampening solution into the water fountain
on the first unit and second unit to the proper leveL
i
2 1
l
Complete.