16
English
Press ENTER to display the soluble product block parameter.
This function allows the setting of a number of water vends before
blocking.
Press ENTER to display the block parameter.
This function allows the setting of a number of coffee grounds
expulsions before blocking.
Press ENTER to visualize the block parameter.
This function allows the zeroing of all the product quantity partial
counters.
Press ENTER to access this option.
To set this function follow the procedure described in chapter 7.5
Changing and saving parameters:
Confirming the letter ->Y<- zeroes the counters.
This function allows setting the temperature maintained by the de-
vice for a few minutes (about 4) after a drink has been dispensed.
The lower line of the display shows the set value, expressed in
degrees centigrade.
To set the minimum maintained temperature follow the procedure
described in chapter 7.5 Changing and saving parameters.
This function allows the setting of the temperature reached by the
device after a certain period of inactivity (about 4 minutes) to com-
pensate the natural temperature fall.
The lower line of the display shows the set value, expressed in
degrees centigrade.
To set the inactivity temperature follow the procedure described in
chapter 7.5 Changing and saving parameters.
This function allows, only if the mechanic pulse counter is fitted, to
enable or not the total or partial counting of drink vends.
To obtain drink vend total count enable the MECH. COUNTER
BEVERAGE function.
To obtain drink vend total count enable the MECH. COUNTER
BEVERAGE or MECH. COUNTER SOLUBLE functions (only
D.A. 5P) or MECH. COUNTER COFFEE.
To select the count to be enabled follow the procedure described
in chapter 7.5 Changing and saving parameters.
This function allows the setting of the current hour, minute, day,
month and year.
To set the function follow the procedure described in chapter 7.5
Changing and saving parameters.
Repeat the same procedure for all function data.
This function allows the setting of the text that scrolls on the display
when the vending machine is on standby.
To set the text follow the procedure described in chapter 7.5
Changing and saving parameters.
This function allows the setting of the text that scrolls on the display
when the vending machine is dispensing a drink.
To set the text follow the procedure described in chapter 7.5
Changing and saving parameters.
This function allows the setting of the text that scrolls on the display
when the vending machine stops due to a fault.
To set the text follow the procedure described in chapter 7.5
Changing and saving parameters.
This function allows the enabling or not of drink price display.
The lower line of the display shows the set parameter.
By enabling this function (YES) the user is allowed by pressing the
key relating to a drink to visualize its price on the display. After a
few seconds the visualization is cancelled.
Press ENTER to access this option.
To set this option follow the procedure described in chapter 7.5
Changing and saving parameters.
Its the device registration number, set by the manufacturer, and it
can only be displayed.
This function allows the setting of a password (0000 base setting)
to prevent unauthorized personnel from directly accessing program-
ming functions.
If a password is set, it shall always be typed before accessing
programming.
Press ENTER to access this option.
TEXT STAND-BYTEXT STAND-BY
TEXT STAND-BYTEXT STAND-BY
TEXT STAND-BY
*D.A. 5PN SAECO**D.A. 5PN SAECO*
*D.A. 5PN SAECO**D.A. 5PN SAECO*
*D.A. 5PN SAECO*
MECH. COUNTERMECH. COUNTER
MECH. COUNTERMECH. COUNTER
MECH. COUNTER
BEVERAGEBEVERAGE
BEVERAGEBEVERAGE
BEVERAGE
CLOCKCLOCK
CLOCKCLOCK
CLOCK
*09:33 L 05 MAR 97**09:33 L 05 MAR 97*
*09:33 L 05 MAR 97**09:33 L 05 MAR 97*
*09:33 L 05 MAR 97*
TEXT DISPENSINGTEXT DISPENSING
TEXT DISPENSINGTEXT DISPENSING
TEXT DISPENSING
DISPENSINGDISPENSING
DISPENSINGDISPENSING
DISPENSING
TEXT OUT OF SERVTEXT OUT OF SERV
TEXT OUT OF SERVTEXT OUT OF SERV
TEXT OUT OF SERV
OUT OF SERVICEOUT OF SERVICE
OUT OF SERVICEOUT OF SERVICE
OUT OF SERVICE
PRESELECTIONPRESELECTION
PRESELECTIONPRESELECTION
PRESELECTION
YESYES
YESYES
YES
SOLUBLE 1SOLUBLE 1
SOLUBLE 1SOLUBLE 1
SOLUBLE 1
00000 LIM:0050000000 LIM:00500
00000 LIM:0050000000 LIM:00500
00000 LIM:00500
STOP WATERSTOP WATER
STOP WATERSTOP WATER
STOP WATER
00000 LIM:0050000000 LIM:00500
00000 LIM:0050000000 LIM:00500
00000 LIM:00500
STOP GROUNDSSTOP GROUNDS
STOP GROUNDSSTOP GROUNDS
STOP GROUNDS
00000 LIM:0010000000 LIM:00100
00000 LIM:0010000000 LIM:00100
00000 LIM:00100
RESET STOPRESET STOP
RESET STOPRESET STOP
RESET STOP
RESET STOPRESET STOP
RESET STOPRESET STOP
RESET STOP
->Y<- N->Y<- N
->Y<- N->Y<- N
->Y<- N
MIN. TEMPERATUREMIN. TEMPERATURE
MIN. TEMPERATUREMIN. TEMPERATURE
MIN. TEMPERATURE
T:095T:095
T:095T:095
T:095
MIN. TEMPERATUREMIN. TEMPERATURE
MIN. TEMPERATUREMIN. TEMPERATURE
MIN. TEMPERATURE
T:100T:100
T:100T:100
T:100
PRESELECTIONPRESELECTION
PRESELECTIONPRESELECTION
PRESELECTION
->Y<- N->Y<- N
->Y<- N->Y<- N
->Y<- N
SERIAL NUMBERSERIAL NUMBER
SERIAL NUMBERSERIAL NUMBER
SERIAL NUMBER
909024909024
909024909024
909024
CHANGE PASSWORDCHANGE PASSWORD
CHANGE PASSWORDCHANGE PASSWORD
CHANGE PASSWORD

Table of Contents

Related product manuals