4
0715
Technical Data
General
Illuminated red distress button with transparent cover for each section.
Indicator Alarm Panel with distress annunciator and status information for each connected
unit.
Audible alarm for indication of distress alert transmission in progress, or distress or urgency
calls received.
Dimmer push button for controlling light intensity in the indicator Alarm Panel.
Mute push button for resetting the audio alarm.
Test push button for verification of indicators, audible alarm and push buttons.
All distress functions work fully independent of each other.
All control signals are galvanically isolated by opto-couplers.
The indication line in the display goes off if the connection to the associated transceiver is
broken. When the connection is re-established it may take up to 20 seconds before it is
indicated in the display.
Supply Voltage: 24 V DC (21 V to 32 V)
Current consumption: max.100 mA
Operating temperature range: -20°C to +55°C
Compass safe distance: Standard: 0.9 m. Steering: 0.6 m.